Enroll a home battery in a virtual power plant when the payment is larger than what you give up on event days (some time-of-use savings, some backup and some warranty throughput), and when the contract lets you override events, keeps a reserve floor you can live with and lets you leave without a large repayment. Published programs pay in four main ways: a one-time amount per kW or kWh enrolled, a yearly amount per kW of average output, a monthly fee plus a payment per kWh delivered, or quarterly payments. In return, the program may discharge your battery during a capped number of events, usually two to six hours long, down to a floor such as 20%.
The terms below are quoted from program pages as published in November 2026, and programs change them often. This guide reads five published battery programs side by side, then works through what an event does to a time-of-use bill, to backup and to the warranty. Culni runs no virtual power plant, has no program partnerships and is not affiliated with any utility or program named here.
What a virtual power plant is and who runs one
A virtual power plant (VPP) is a group of small devices, such as home batteries, smart thermostats and EV chargers, that an operator dispatches together so they act like one power plant. Austin Energy’s November 16, 2026 release defines it in nearly those words. For a battery owner, the practical meaning is simple: on certain days, someone other than you decides when your battery discharges.
Three kinds of operators run them, and the kind decides who writes your contract and who pays you.
Utility programs
Most home battery VPPs open to homeowners today are utility programs. The utility sets the payment, the event rules and the eligibility, and sends its signals through the battery manufacturer’s cloud or a vendor. Austin Energy in Texas, SMUD in Sacramento, Green Mountain Power in Vermont and LG&E and KU in Kentucky all publish battery programs, and their terms differ more than their names suggest.
Your electricity rate does not change because you enroll, but some programs require a particular rate. Austin Energy says a participant’s bill is still calculated on its standard residential rates and Value of Solar credit. SMUD requires participants to be on its Solar and Storage Rate.
State programs
California also runs a statewide program through the California Energy Commission. Its Demand Side Grid Support program “will offer incentives to electric customers that provide load reduction and backup generation” during extreme events from May to October. It was authorized by Assembly Bill 205 in 2022 and pays “with upfront capacity commitments and for per-unit reductions in net load.”
Homeowners do not sign up with the state. The program administrator’s site limits direct enrollment to non-residential participants in an option that is suspended for 2026; everyone else enrolls through a DSGS provider. Its storage option pays capacity payments based on demonstrated kW and duration (2, 3 or 4 hours), with dispatch between 4 and 9 p.m., seven days a week.
The Solar Energy Industries Association’s December 2025 factsheet (read in an April 12, 2026 archived copy, because the live file refuses automated requests) describes the program as “a statewide virtual power plant network composed of more than 100,000 home batteries.” Citing The Brattle Group, it says two companies’ batteries delivered an average of 539 MW during a July 29 dispatch from 7 to 9 p.m. SEIA is the solar industry’s trade association, so treat its framing as advocacy.
Wholesale markets under FERC Order 2222
FERC Order No. 2222, issued September 17, 2020 in Docket RM18-9-000 and updated by Orders 2222-A and 2222-B in 2021, requires regional grid operators to let aggregations of distributed energy resources sell into their wholesale markets. FERC’s explainer (read in an October 8, 2026 archived copy, because the live page refuses automated requests) says aggregations can be as small as 100 kW and names battery storage, rooftop solar, smart thermostats and EV charging equipment as eligible resources.
A homeowner’s participation “would typically be indirect.” An aggregator bundles many devices, sells into the market and shares compensation “according to the terms of a contract.” The order applies only inside the regions run by regional transmission organizations and independent system operators (RTOs and ISOs), and FERC notes it does not apply in Texas’s ERCOT area.
For scale, the Department of Energy’s VPP Liftoff page (read in a May 2, 2025 archived copy of liftoff.energy.gov/vpp) said “VPP scale has grown to 33 GW across North America.” It set out a path of 80 to 160 GW by 2030, enough to serve 10 to 20% of peak load.
What happens to your battery during an event
An event is a period, usually a few hours, when the program operator controls your battery’s discharge. Here is the sequence as Austin Energy describes it on its Power Partner Battery page, with the differences other programs publish.
- Enrollment through the manufacturer. Austin Energy has owners register an eligible battery in the manufacturer’s app. Green Mountain Power also enrolls some brands through their apps. Either way, the control signal travels through the manufacturer’s cloud or the program’s vendor, not through your own settings.
- Notice. Austin Energy does not send event notifications itself. They are set by the battery manufacturer and appear in the battery app before and during events. Green Mountain Power promises notice “at least four hours in advance.”
- Discharge. The battery covers your home’s load first, then exports the rest. Austin Energy’s FAQ says events “will serve the home’s electricity needs first before being exported to the grid.”
- The floor. Discharge stops at a reserve. Austin Energy says its events will not take a battery below 20 percent, and SMUD says it “will always leave customers with a 20% reserve at the end of an event.”
- Length. Austin Energy events typically last two to three hours. Green Mountain Power expects events to average three to six hours. California’s storage dispatch falls between 4 and 9 p.m.
- Recharge. Austin Energy says batteries “will typically regain full charge within less than 24 hours.” Until then, your backup is whatever the event left.
- Override. In Austin you can override an event before or during it in the manufacturer’s app, except that Enphase systems allow opting out only up to five minutes before the start. There is no penalty, but each opt-out lowers the annual payment.
Storms get special handling in Austin. The utility says it will typically not call events when a severe storm is forecast. If a battery’s storm mode activates during an event, storm mode overrides the utility’s control and charges the battery to 100 percent.
How programs pay: five published offers side by side
Programs pay for one of three things: your commitment (an upfront amount), your availability (a fixed monthly or quarterly amount) or your performance (kW or kWh delivered during events). Most mix two of them. The table lists what each program page published when checked on November 22, 2026.
| Program (operator, state) | Upfront payment | Ongoing payment | Event rules published | Reserve during events |
|---|---|---|---|---|
| Power Partner Battery (Austin Energy, Texas) | $500 per battery system with permission to operate on or after February 18, 2025 | $75 per kW of average output during events, paid yearly | Up to 40 a year, not counting grid emergencies; any day, any hour; typically 2 to 3 hours | Not below 20% |
| My Energy Optimizer Partner+ (SMUD, California) | Up to $10,000 per household ($500 per kWh) if submitted for interconnection by September 22 and enrolled by December 31, 2026; $300 per kWh, up to $6,000, for applications from September 23 | Quarterly, for Tesla batteries only: $110 for one battery, $220 for two, $330 for three or more | Not stated on the program page | 20% left at the end of each event |
| Bring Your Own Device (Green Mountain Power, Vermont) | $850 per kW enrolled for three-hour discharge, $950 per kW for four-hour; rebate up to $10,500 | None listed | Average of 5 to 8 a month, 3 to 6 hours each; notice at least 4 hours ahead | No fixed floor stated |
| Bring Your Own Battery pilot (LG&E and KU, Kentucky) | None listed | $20 a month plus $1 for every kWh the battery delivers during events | Not yet published; the pilot is listed as coming soon | Not yet published |
| Demand Side Grid Support, storage option (California Energy Commission) | None published by the state | Capacity payments based on demonstrated kW and duration; homeowners take part through a DSGS provider | May to October, 4 to 9 p.m., seven days a week | Not stated on the administrator’s page |
Sources: Austin Energy, SMUD, Green Mountain Power, LG&E and KU and the DSGS administrator. SMUD’s page says its incentive table assumes a 20% reserve.
What each payment structure rewards
Per kW of average output. Austin Energy pays $75 a year for each kW your battery averages across its events. Its own example, a Tesla Powerwall: a 13.5 kWh battery with a 20% reserve offers 10.8 kWh; spread over a 2.5-hour average event, that is 10.8 ÷ 2.5 = 4.32 kW, and 4.32 × $75 is about $324 a year. Opting out of events or setting a shallower discharge lowers the average and the check.
Upfront per kW or kWh. Green Mountain Power and SMUD pay mostly at enrollment. The amount is fixed whether the year brings many events or few, so an upfront offer can come with a long term and a repayment clause, as Green Mountain Power’s does (see “Term, exit and repayment” below).
Monthly plus per kWh. LG&E and KU’s pilot is set to pay $20 a month, or $240 a year, for being available, plus $1 for each kWh delivered during events. Suppose the pilot called 20 events and the battery delivered 10 kWh in each: 20 × 10 × $1 = $200, for $440 in the year. The event count here is hypothetical; LG&E and KU have not published one.
Value per event. A yearly payment divided by the number of events tells you what each event is worth to you. Under Austin’s structure, $324 spread over all 40 allowed events is $8.10 an event; spread over ten events it is $32.40. That per-event figure is what you compare with the per-event costs worked out later in this guide.
What a trade group says a fair program looks like
SEIA’s factsheet lists the terms the solar industry asks regulators for. It says payments “typically fall in the $200-$300/kW” range “for average performance over the event season,” and that the payment level should be locked in “for at least 5 years.” It also asks for events no longer than three hours, 30 to 60 events a year, no opt-out fee or limit, and payments that can be stacked with other programs.
Austin Energy’s $75 per kW a year sits well below that range. Utilities set payments from their own avoided costs, so SEIA’s figures show what the industry argues for, not what your utility owes you. They are still a useful yardstick when a program offers short events, many opt-outs and a locked payment.
What the contract commits you to
The payment is the headline; the commitments are in the terms and conditions. Read these seven items before you enroll, in this order.
Event cap, window and length
Austin Energy allows up to 40 events a year “excluding grid emergencies,” on any day and at any time, including weekdays and holidays. Green Mountain Power expects an average of five to eight events a month, each three to six hours. California’s storage option dispatches between 4 and 9 p.m. from May to October.
A cap that excludes emergencies is not a cap on emergencies. Ask for the maximum number of events per year and per season, the longest event allowed, the hours they can start, and whether events can run on consecutive days.
Notice and overrides
Notice tells you whether you can prepare: charge the car first, pre-cool the house, or decide to opt out. Green Mountain Power promises at least four hours; Austin Energy leaves notice to the manufacturer’s app. Austin lets you opt out of any event without penalty, though each opt-out reduces the annual payment, and Enphase systems lock the choice five minutes before the start.
Ask how many opt-outs are allowed before you are removed, whether an opt-out forfeits a whole season’s payment or only that event’s share, and whether you can opt out of a single event from the app or only by contacting the program.
How deep each event goes
The floor decides your backup after an event. Austin Energy and SMUD both cite 20%. Austin Energy also says some battery vendors can help you limit how much the system discharges during events, which lowers what it earns.
Ask whether the floor is a fixed percentage or your own reserve setting, and whether you can raise it for a season. A program that discharges to 20% when you normally keep 40% for storms changes your outage plan on every event day.
Term, exit and repayment
Upfront money can buy a term. The customer agreement linked from Green Mountain Power’s program page, dated November 2020, has the customer repay a prorated share of the upfront incentive if the agreement ends early. Its worked example divides the time left by 120 months: with 48 months left on a $950 per kW incentive, the customer owes 48 ÷ 120 × $950 = $380 per kW.
SMUD requires enrollment within 90 days of receiving permission to operate to get the enrollment incentive, and its terms document holds the rest. Austin Energy’s page describes unenrolling by form or email and does not mention repaying the $500 rebate. In every program, ask what happens when you sell the house: does the agreement transfer to the buyer, or does the repayment fall due at closing?
Eligibility, rate and ownership
Programs restrict who can join. SMUD requires its Solar and Storage Rate, excludes customers on its medical equipment discount rate and treats individual rental units as ineligible. Austin Energy excludes third-party-owned batteries, does not require solar and does not limit how many batteries you enroll. LG&E and KU’s pilot is for residential-style batteries on Rate RS and Rate GS.
A required rate can move your bill more than the incentive does. Before enrolling in a program that requires a specific rate, compare that rate with your current one using a year of your own bills.
Connectivity and other uses of the battery
Green Mountain Power requires an internet connection to the battery “at all times.” If GMP loses the connection, you have 30 days to restore it before the system is removed from the program and the termination clause applies. Battery warranties have their own connectivity rules, covered in the home battery warranty guide.
The largest commitment in the table is easy to miss. Green Mountain Power’s requirements say: “You must use the battery for home back-up power only,” and you may not use it “for any controls other than providing backup power.” Under those terms, the battery does not run your own daily time-of-use schedule or self-consumption mode; outside the program’s peak events, its job is backup.
Stacking programs
Some programs bar double payment. California’s DSGS administrator says participants cannot be paid by other utility, community choice or state demand response programs during overlapping DSGS event intervals, apart from their rate plan. FERC’s Order 2222 likewise asks grid operators to write rules “with the goal of avoiding duplicative compensation for the same services.”
SEIA argues the opposite should hold, that payments be “stackable.” Until your program says so in writing, assume a battery in one program cannot be paid by a second program for the same hours.
How events change your time-of-use savings
On a time-of-use rate, an event costs you two things: the peak-hour energy the battery would have covered for your house later that day, and the extra energy needed to refill it afterward. The cost depends mostly on when the event falls relative to your own peak window. An event inside the hours when your battery would discharge anyway costs little; an event before your peak can leave the battery at its floor when the expensive hours start.
Example (fictional). The site’s example home is a fictional Louisville-area house with 7.6 kW of solar, a 13.5 kWh battery (5 kW, 20% reserve of 2.7 kWh, 85% round-trip efficiency) and an example rate: 8 cents off-peak (9 p.m. to 7 a.m.), 14 cents in the day (7 a.m. to 4 p.m.), 31 cents at the 4 to 9 p.m. weekday peak, and a 7 cent export credit. On a clear April weekday with its schedule, the battery fills from solar by noon, holds, covers the house from 5 to 9 p.m. and ends the peak with 5.7 kWh. The day nets $0.60.
Now add one event in a hypothetical program. Assumptions: the battery discharges at its full 5 kW until it reaches the 2.7 kWh reserve; the house uses that energy first and the rest is exported; exported kWh earn the example’s 7 cent credit; the 85% round-trip loss is split evenly, about 92.2% each way; and the next morning the battery refills from solar that would otherwise have been exported.
For a 6 to 8 p.m. event:
- 5 to 6 p.m.: the battery covers the house’s 1.0 kWh, as on a normal day.
- 6 to 8 p.m.: it delivers 5.0 kWh, then 4.0 kWh more before it hits the reserve, 9.0 kWh in all. The house uses 2.1 + 2.2 = 4.3 kWh of it and about 4.7 kWh is exported, earning 4.66 × $0.07 = $0.33.
- 8 to 9 p.m.: the battery is at its reserve, so the house buys 1.9 kWh at peak: 1.9 × $0.31 = $0.59.
- Change in the day’s net cost: $0.59 − $0.33 = $0.26.
- Next morning: the battery starts at 2.7 kWh instead of 5.7 kWh. Storing the extra 3.0 kWh takes 3.0 ÷ 0.922 = 3.24 kWh of solar, which would have earned 3.24 × $0.07 = $0.23 as export.
- Bill cost of the event: $0.26 + $0.23 = $0.49.
The same arithmetic for other event windows:
| Event window | Battery delivers in the event | Peak kWh the house buys | Change in that day’s net cost | Next-day refill (lost export credit) | Bill cost of the event |
|---|---|---|---|---|---|
| No event | 0 | 0 | none (day nets $0.60) | none | none |
| 7 to 9 p.m. | 6.9 kWh | 0.04 kWh | −$0.18 | $0.23 | $0.04 |
| 6 to 8 p.m. | 9.0 kWh | 1.9 kWh | +$0.26 | $0.23 | $0.49 |
| 5 to 7 p.m. | 10.0 kWh | 4.1 kWh | +$0.79 | $0.23 | $1.02 |
| 2 to 4 p.m. | 10.0 kWh | 6.6 kWh | +$1.40 | $0.23 | $1.63 |
In the 7 to 9 p.m. row the export credit on 2.8 kWh nearly cancels the next-day refill. In the 2 to 4 p.m. row the battery is at its reserve before the peak starts and the house buys 6.6 kWh at 31 cents, which is $2.05, partly offset by $0.65 of extra export credit.
This is one clear spring weekday at an example rate, not a month or a year. Cloudy days, winter, weekends and your real rate change every number, and a real plan models each day type.
Reading the result for your own home
The example points to a simple rule. The closer an event sits to the hours when your battery already discharges for your rate, the less it costs you, because the program is mostly buying energy you would have spent anyway. The further ahead of your peak it falls, the more peak energy you buy back.
Weigh that against the payment. In the example, the worst of the four timings costs $1.63, while a program paying $1 per kWh delivered would pay about $10 for that event if every delivered kWh counted, and Austin Energy’s structure pays $8.10 to $32.40 per event for its own example battery, depending on how many events it calls. On these example numbers the bill cost is the smaller term; backup exposure and contract terms are the larger ones.
A home on a flat rate faces a different calculation, because its battery is not avoiding peak prices. Suppose a battery kept full for backup at a hypothetical flat 13 cents per kWh is discharged from 13.5 kWh to 2.7 kWh in an event. Refilling 10.8 kWh at 85% round-trip efficiency takes 10.8 ÷ 0.85 = 12.7 kWh, at most 12.7 × $0.13 = $1.65 from the grid, less whatever the delivered energy saved the house during the event and any export credit.
A four-step check before you compare offers
- Write down the hours your battery discharges for your rate on each day type (weekday, weekend, summer, winter). The battery scheduling page explains how a schedule is built from rate windows.
- Write down the program’s event window, maximum event length and maximum number of events.
- For the worst overlap, work out the peak kWh you would buy back and the refill energy, using your own rate and export credit.
- Divide the program’s yearly payment by the maximum number of events and compare the result with step 3.
What events do to your backup
An event leaves the battery at the program’s floor, and it may stay there until solar or off-peak charging refills it the next day. If an outage starts in that window, your backup is the floor, not the full battery. For a household that bought its battery for outages, that is the main cost of a VPP.
The site’s backup runtime calculator shows the size of the gap. Its default inputs are a 13.5 kWh battery starting at 20%, a 330 W critical load and 95% inverter efficiency. That gives 13.5 × 0.20 × 0.95 = 2.6 kWh for the loads, or about 7.8 hours, compared with roughly a full day and a half from a full battery at the same load (13.5 × 0.95 ÷ 0.33 = 38.9 hours).
Programs handle storms differently:
- Austin Energy says it will typically not call events when a severe storm is forecast, and a battery’s storm mode overrides the utility’s control and charges to 100 percent.
- SMUD says it leaves the 20% reserve “in case of an outage overnight” and that participants “will have full access to the amount of power available” in the battery during an outage.
- Green Mountain Power says it will make adjustments when possible to avoid fully discharging a battery before or during pending weather events, but that it cannot promise the battery will be charged to a minimum level at all times.
Before enrolling, decide what reserve you need on ordinary days and before storms. The battery reserve before storms article covers that choice in depth, and the backup reserve page explains how a schedule raises the reserve ahead of a forecast storm. If anyone in the home depends on powered medical equipment, talk to your utility about its medical programs before giving an outside party control of the battery.
The warranty throughput events use
Every kWh discharged during an event counts toward the cycle and throughput limits in your battery warranty. Many battery warranties end at a number of years or at a cap on cycles or delivered energy, whichever comes first, so extra discharge can bring the end date closer.
The scale is easy to estimate. A 13.5 kWh battery with a 20% floor can deliver up to 10.8 kWh per event. If a program called all 40 events Austin Energy allows, at that depth they would add 40 × 10.8 = 432 kWh a year, or 432 ÷ 13.5 = 32 full cycles. Enphase’s warranty for its IQ Battery 3, 3T, 10 and 10T caps coverage at 2.8 MWh of AC throughput per kWh of rated capacity, so a 13.5 kWh battery under the same terms would have 2.8 × 13.5 = 37.8 MWh, and 432 kWh is about 1.1% of that a year.
On a time-of-use rate much of that energy would have been discharged anyway. In the fictional example above, the 6 to 8 p.m. event took the battery from 13.5 kWh to 2.7 kWh, a 10.8 kWh swing, against 7.8 kWh on a normal day. The extra is 3.0 kWh per event, or 120 kWh across 40 events.
A battery that otherwise sits full for backup is different: every event is new throughput. At Green Mountain Power’s expected five to eight events a month, a battery delivering 10.8 kWh per event would add 60 × 10.8 = 648 to 96 × 10.8 = 1,037 kWh a year, 48 to 77 full cycles of a 13.5 kWh battery.
Warranties can also limit who controls the battery. SolarEdge’s warranty for its Home Battery 48V (read in a March 30, 2024 archived copy) covers batteries used in listed modes, including “SolarEdge-managed Grid Services or approved 3rd party management systems.” Ask the manufacturer in writing whether the program’s control path is one the warranty accepts. The home battery warranty guide converts these caps into years for daily cycling.
Data and control: who talks to your battery
Enrolling gives an outside party a control channel into your battery and a stream of data out of it. Austin Energy says it “remotely adjusts enrolled batteries,” with events set through the battery manufacturer. LG&E and KU name EnergyHub as the vendor that will contact interested customers about their pilot. California’s storage option runs through the DSGS provider you sign with.
None of the program pages checked for this guide spell out what battery data the operator collects or how long it keeps it. Ask before you enroll:
- What the operator reads from the battery (state of charge, power, settings), how often, and who else receives it.
- How long the data is kept, and whether it is deleted or kept when you leave the program.
- Whether you keep full access to your own data in the manufacturer’s app during and after enrollment.
- Whether the operator can change settings other than discharge during events, such as the reserve or the operating mode.
The security and data page explains how Culni, which writes a daily schedule for a home’s battery, solar and EV charging from its electricity rate, handles device permissions and data. If you use scheduling software alongside a program, the program’s event control comes first on event days. Culni’s home energy plan lists the utility programs relevant to a home and says what the daily schedule would and would not do on event days, but Culni does not enroll anyone in a program.
Kentucky: what LG&E and KU customers can do now
LG&E and KU list a Bring Your Own Battery pilot as coming soon on their energy efficiency programs page. The page says participants will receive “$20 per month and $1 for every kWh of energy your battery delivers during events,” that “Pilot capacity is limited,” and that interested customers will be invited “on a first-come, first-served basis as openings become available.”
The interest list form says the pilot “will only be available to customers with residential-style batteries” on Rate RS and Rate GS, names EnergyHub as the vendor, and adds: “No commitment required. Joining the interest list does not enroll you in the program.” The event count, event length, notice, reserve floor and term were not published when checked. Those are the questions to ask when the invitation comes.
Two Kentucky details change the arithmetic in this guide:
- The rate. The pilot is listed for Rate RS and Rate GS; the time-of-day rates are not named. On a flat energy charge, an event does not displace peak-priced energy; its cost is mainly the refill energy and the backup you give up until the battery recharges.
- Wholesale aggregation. FERC Order 2222 reaches only homes inside an RTO or ISO region. FERC’s explainer includes a map; your utility can tell you whether its service area is in one.
LG&E and KU also run thermostat and EV charging programs; see thermostat demand response and the electric vehicles hub. The battery homes page covers where utility battery programs fit in a battery plan. Culni is not affiliated with LG&E, KU or any of their programs.
Before you enroll: a checklist
Get the program’s full terms and conditions as a PDF, not only the web page, and answer these questions from it.
- Payment type. Upfront per kW or kWh, yearly per kW, monthly, per kWh delivered, or a mix. Write the yearly total for your battery size.
- Payment lock. How long the payment level is fixed, and whether the operator can change it during your term.
- Event cap. Maximum events per year and per season, and which events (emergencies, tests) do not count.
- Event window and length. Which hours, which days, the longest event, and whether events can run on consecutive days.
- Notice. How far ahead you hear, and through which app or message.
- Overrides. How to opt out, the cutoff time, how many opt-outs are allowed, and what each one costs.
- Floor. The lowest state of charge an event can reach, and whether your own reserve setting applies.
- Storms. Whether events are skipped before forecast storms, and whether storm mode overrides the program.
- Term and exit. Minimum term, repayment formula, and what happens when you sell the house.
- Rate and eligibility. Any required rate, ownership limits (leased or third-party-owned systems) and eligible battery models.
- Other uses. Whether you may keep running your own time-of-use schedule or self-consumption mode outside events.
- Stacking. Whether you can stay in other programs or keep other payments.
- Data. What is collected, who receives it, how long it is kept, and what happens to it when you leave.
- Warranty. A written answer from the manufacturer that the program’s control path and extra cycling do not affect coverage.
The home battery checklist has the hardware questions to settle first.
What to do next
Start with your own numbers. Find your rate windows and export credit, list the hours your battery discharges on each day type, and work out the per-event cost for the program’s worst event timing, as in the example above. The battery arbitrage calculator shows what a normal discharge day is worth on your rate, which is the value an event can displace.
Then set the reserve you need for outages, and check it against the program’s floor with the backup runtime calculator. If the program’s floor is lower than the reserve you would choose, ask whether you can raise it, and price the difference into your decision.
If you would like the trade-off written out for your home, Culni’s home energy plan reads your rate, lists the programs that apply to your utility and shows what the schedule would and would not do on event days. You can send your rate plan, a recent bill and your device list through the contact page. Enrollment decisions, and the contract, stay between you and the program.