5 to 9 p.m.
in the example home
Backup reserve
How much battery to keep for outages, when it rises, and what it costs in daily savings.
- 5 p.m. to 9 p.m. runs the house above the reserve
- You send
- Critical loads, hours wanted, battery size, backup wiring
- You get
- A reserve with hours of backup for the loads you list
- Stays with you
- The reserve level and the storm-season months
- Limits
- Backup depends on your hardware and how it was installed

A battery cannot spend the same kWh twice. Energy used to cover the 6 p.m. peak is not there when a storm takes the power out at 2 a.m. The backup reserve is the share of the battery you keep back for outages. You choose it, the schedule never plans below it, and it can rise on its own before bad weather. This page covers how to choose it, what it buys and what it costs.
How often the power goes out
The EIA reported in December 2025 that US electricity customers averaged 11 hours of interruptions in 2024, “nearly twice as many as the annual average experienced in the decade before”. Major events caused 80% of those hours. Interruptions outside major events “routinely average about two hours per year”. The spread is wide: customers in South Carolina averaged nearly 53 hours. In 2022, the US average was about five and a half hours.
Two things follow. Most outage time arrives in a few large events, not spread evenly across the year. And your own exposure depends on where you live, so the plan asks about your outage history instead of assuming the national average.
What the reserve buys
A reserve is measured in hours of backup for the loads you list, at the reserve you choose. Plan for the worst case: an outage that starts right after the evening peak, when the battery is down to its reserve.
Example (fictional). The example home’s battery holds 13.5 kWh usable, with a 20% reserve: 2.7 kWh. Its critical loads (a refrigerator, the internet router, LED lights and phone charging) average 330 W. With a 95% efficient inverter and no solar recharging, the backup runtime calculator gives 2.6 kWh available and about 7.8 hours of backup. On the scheduled April weekday the battery ends the peak with 5.7 kWh, more than double the reserve, so an outage that evening would start well above the worst case.
The trade-off with daily savings
Every kWh held for outages is a kWh that cannot cover the peak. In the example home, the battery delivers 7.2 kWh to the house from 5 to 9 p.m. on a clear April weekday. Here is what different reserves would mean on that day (fictional example; backup hours from the backup runtime calculator at 330 W, 95% inverter efficiency, no solar recharging):
| Reserve | Kept for outages | Left for daily use | Backup, worst case | The 5 to 9 p.m. peak |
|---|---|---|---|---|
| 20% | 2.7 kWh | 10.8 kWh | About 7.8 hours | Fully covered by the battery |
| 40% | 5.4 kWh | 8.1 kWh | About 15.5 hours | Still fully covered |
| 60% | 8.1 kWh | 5.4 kWh | About 23.3 hours | About 2.2 kWh bought at the peak price |
| 100% | 13.5 kWh | None | About 38.9 hours | All 7.2 kWh bought at the peak price |
The table shows why one reserve for the whole year is rarely the right answer. On most days a modest reserve does the daily work. On the few days when an outage is likely, a full battery is worth a day of peak purchases. Your plan shows this table for your own battery, loads and rate.
Storm-season reserve
Two settings let the reserve change with the risk:
- Storm watch. When a storm watch covers your area, the reserve rises ahead of it, to a level you choose (often 100%). The battery fills from solar, or from the grid where your equipment and interconnection agreement allow grid charging, and stays full until the watch ends.
- Seasonal reserve. For the months when outages are more likely where you live, a higher everyday reserve. You choose the months.
Both cost something on the days they apply, and the plan states that cost. Some battery apps have a storm mode of their own; the plan says which one is in charge, so the two do not fight.
Critical loads and how your system is wired
Backup depends on the hardware and how it was installed, not on the schedule.
- Partial or whole-home. Many systems back up a separate panel of critical circuits; others connect at the main panel. Only circuits the installer connected to the battery receive backup power.
- Power, not just energy. The example battery delivers at most 5 kW. Motor loads such as well pumps and central air can need more power at start-up than a battery can supply.
- Solar during an outage. Whether the panels keep charging the battery when the grid is down depends on how the system was designed and installed.
Culni does not change wiring, the backup panel or transfer equipment. If a load you need is not on a backed-up circuit, that is a question for your installer or electrician. List your loads with the battery sizing worksheet, and go through the outage readiness checklist before storm season.
Utility battery programs
Some utilities pay battery owners to discharge during grid events. LG&E and KU list a Bring Your Own Battery pilot as coming soon. If you join a program like that, events may draw the battery down on event days, and the program’s instructions take priority. Your plan says what the program allows and how your reserve is treated on those days. Culni is not affiliated with any utility program and does not enroll you.
What Culni will not do
- It will not schedule the battery below your reserve for savings.
- It will not describe backup as anything more than hours for the loads you list, at the reserve you choose. What you actually get in an outage depends on the hardware, the installation and the state of charge when the outage begins.
- It will not change wiring, gateway or transfer settings, or anything in your interconnection agreement.
- It will not promise a control path it has not confirmed. If the reserve cannot be set remotely in your home, the plan gives you the setting to enter by hand.
What you send and what you get
Send a list of the loads you want covered in an outage (or the completed sizing worksheet), how many hours you want them covered, the battery’s usable capacity and power rating, and how backup was installed; the installer’s commissioning summary usually has it. You get a reserve setting with the hours of backup it gives for the loads you listed, storm-watch and seasonal rules, and the cost of each in daily savings. The battery scheduling page shows how the rest of the battery is used.
TodayYour turn
Send your rate and your devices
Your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan: your rate decoded, which devices can connect, the daily schedule and its estimated value with every assumption shown.
Remote. No site visit needed.