How the battery should run on your rate, how much to hold for outages, and where utility programs fit.

  • 8 a.m. to 11 a.m. charges from solar
  • 11 a.m. to 5 p.m. holds for the peak
  • 5 p.m. to 9 p.m. runs the house
You send
Battery model, usable kWh, mode, reserve and backup circuits
You get
A schedule by day type and hours of backup at your reserve
Stays with you
The reserve level and any program enrollment
Limits
Value depends on the rate, backup on the installation
A squirrel tucks acorns into a hollow in an old tree trunk beside a house, where a small pile is already stored.

A home battery is worth what it moves. Each day it can store energy when energy is cheap or would otherwise be exported, and give it back when power costs more or when the grid is down. How much that is worth depends on four things: the mode the battery runs in, the reserve you hold for outages, the programs you join, and the rate you are billed on. You control the first three. The rate is usually the one that decides the most.

Solar plus storage, or storage alone

With solar, the battery’s first everyday job is to keep surplus from the panels in the house instead of sending it out for an export credit. Without solar, the battery can only charge from the grid, so its everyday value comes from a price difference between hours, and only where your equipment and interconnection agreement allow grid charging.

Either way, the battery also holds energy for outages. Whether it can run part of your house during an outage depends on how it was installed: which circuits it backs up, and whether the transfer equipment is in place. Culni does not change wiring, so the plan works with the backup your installer set up and gives hours of backup for the loads you list, at the reserve you choose.

Modes, and what they leave on the table

Most battery apps offer a self-use mode, a backup-only mode and some form of time-based mode.

  • Self-use spends stored energy as soon as the house needs it. That is right on a flat rate and often wrong on a time-of-use rate, because the battery can be half empty before the expensive hours start.
  • Backup-only keeps the battery full and does nothing on ordinary days.
  • Time-based modes work if someone enters the rate windows correctly for every season and day type, and updates them when the rate changes.

Culni writes that schedule from your rate and runs it daily: charge from solar surplus, hold through the cheaper hours, run the house in the most expensive window, and never go below your reserve. Battery scheduling explains each instruction and the reason it carries.

Value depends on the rate

A battery loses energy on every cycle. NREL uses 85% as a representative round-trip efficiency for home batteries, so a stored kWh comes back as about 0.85 kWh. That loss decides whether shifting pays.

  • On a flat rate, the battery gains only from self-consumption. On LG&E’s Rate RS ($0.11499 per kWh from September 1, 2026, base charge before riders and taxes) with the NMS-2 export credit of $0.07089, a kWh of surplus stored and used later is worth about 2.7 cents.
  • On NMS-1 with a flat rate, each exported kWh earns a kWh credit, so storing surplus mostly adds the round-trip loss. There the battery’s main job is backup.
  • On a time-of-use rate with a wide gap between peak and off-peak prices, the same stored kWh replaces energy bought at the peak price and is worth several times more.

The battery arbitrage calculator shows the arithmetic with your own prices. If your rate leaves little to work with, the plan says so, and the reserve becomes the setting that matters most.

Reserve and storm readiness

The reserve is the share of the battery the schedule never spends. A higher reserve gives more hours of backup for the loads you list and leaves less energy for everyday savings. US customers averaged 11 hours of interruptions in 2024, according to EIA, nearly twice the average of the decade before, and major events caused 80% of those hours. That makes the reserve a real decision rather than a factory default.

Culni can raise the reserve ahead of a forecast storm and bring it back down afterward. Backup reserve explains how, and the outage readiness checklist helps you list the loads that matter.

Example (fictional). The example home’s 13.5 kWh battery normally keeps a 20% reserve (2.7 kWh). Suppose a storm watch raises it to 60% (8.1 kWh) for one clear April weekday, with everything else unchanged: the same solar and household use, the car charging from 1 a.m., and the example rate (31 cents at the 4 to 9 p.m. peak, 8 cents off-peak, 7 cent export credit).

Everyday reserve, 20% Storm watch reserve, 60%
Energy held for outages 2.7 kWh 8.1 kWh
Hours for listed loads averaging 330 W about 7.8 about 23
Bought in the peak that day 0 kWh 2.2 kWh
Net cost for the day $0.60 $1.10

The storm watch costs $0.50 on this day and roughly triples the hours of backup for those loads. Because the battery ended the peak with 5.7 kWh anyway, a reserve of up to about 40% would have cost nothing that day. Hours assume the outage starts with the battery at its reserve and a 95% inverter efficiency, as in the backup runtime calculator. One clear spring weekday is not a month or a year.

Utility battery programs

Some utilities pay homeowners to let the utility discharge their batteries during grid events. LG&E and KU list a Bring Your Own Battery pilot as coming soon, for customers on RS and GS rates, at $20 per month and $1 for every kWh the battery delivers during events. Culni is not affiliated with LG&E, KU or the pilot and cannot enroll you. If you join a program like this, the utility’s event instructions take priority on event days, and your plan shows what Culni would and would not do on those days.

What you send and what you get

Send the battery’s make and model, usable capacity, power rating, current mode and reserve, and what it backs up (the whole panel or selected circuits). A screenshot of the app’s settings and your installer’s commissioning summary are enough. Add your rate plan and a recent bill. The home battery checklist lists the questions to answer first.

You get an hour-by-hour schedule for each day type, the reserve with the hours of backup it gives for the loads you list, how a storm watch changes it, which programs fit, and the estimated value with every input shown. Each month the bill check compares that estimate with your bill.

TodayYour turn

Send your rate and your devices

Your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan: your rate decoded, which devices can connect, the daily schedule and its estimated value with every assumption shown.

Remote. No site visit needed.