Culni homeCheck my home
Menu

Residential demand charges: how a kW charge works and how to keep it low

A residential demand charge bills your highest 15-minute or hourly kW, not only your kWh. See how it is measured, which habits set it and how to keep it low.

Reader question
What is a demand charge on a home electric bill, how is it measured, and which household habits set it?
Two identical wooden gates stand in a meadow: a flock of sheep jams through one all at once while the same number walk through the other in single file.

A residential demand charge is a price per kilowatt (kW) applied to the highest rate at which your home drew power during the billing month, usually measured as the average over the busiest 15-minute or 60-minute interval. It comes on top of an energy charge per kWh, which on a demand rate is usually lower than on the standard rate. The habit that sets it is stacking: running the EV charger, the dryer, the oven, the water heater or electric backup heat at the same time, especially inside the utility’s peak hours. On LG&E’s optional RTOD-Demand rate in Kentucky, each kW of that highest interval costs $4.32 a month, and $13.78 if it falls inside peak hours, according to the tariff checked in November 2026.

Demand rates are still the exception for homes, so this article works through a real residential tariff and a fictional household to show what one crowded evening costs.

What a demand charge is: kW versus kWh

A kilowatt-hour (kWh) measures energy: how much electricity you used over a period. A kilowatt (kW) measures power: how fast you were using it at a moment. The North Carolina Public Staff’s bill guide puts it in car terms: kWh is “analogous to the odometer on your car,” and kW, because it varies over time, is “analogous to the speedometer.” One kW used for one hour is one kWh. A 7.2 kW charger running for two hours uses 14.4 kWh; a 3.6 kW load running for four hours uses the same 14.4 kWh at half the power.

An energy charge multiplies kWh. A demand charge multiplies kW, and only one kW figure per month: the highest. Two homes that use the same kWh can therefore pay very different demand charges. Los Alamos County’s utility illustrates this with two households that each use 60 kWh in a day, one reaching 6 kW at its busiest and the other 3 kW. The first draws twice as much from the grid at its peak, and on a demand rate it pays twice the demand charge.

Utilities charge for kW because some costs follow the peak, not the total. The North Carolina Public Staff explains that “a certain number and size of power plants are necessary to supply the total electrical demand of all customers at a given point in time,” and that the transformer serving your home “must be sized to meet a maximum demand.” RMI, in a 2015 review of residential demand charges, calls it the “size of the pipe”: filling a pool with a fire hose or a garden hose delivers the same water, but the bigger pipe costs more to build.

Most homes never see that cost as a separate line. RMI noted that residential customers “are rarely subject to a bill with a demand charge,” and counted at least 14 utilities with residential demand options at the time; the North Carolina Public Staff says demand charges “are more commonly assessed to commercial and industrial customers.” No current national count exists, because EIA does not collect demand charge data. In the Kentucky example here, the demand charge comes with an optional rate that a household chooses.

How residential demand is measured

Three settings in the tariff decide which number you are billed on: the interval length, the hours that count, and whether the charge looks back at earlier months.

The interval. Meters do not bill the instant a kettle switches on. They average power over an interval and keep the highest average of the month. LG&E’s RTOD-Demand sheet sets the maximum load as “the average kW demand delivered to the Customer during the 15-minute period of maximum use during the month” (Sheet No. 7.1). Los Alamos County’s utility described a one-hour interval instead, based on “the single highest amount of electricity you use during any one hour in your billing period.”

The interval length changes what a brief spike costs. Suppose, hypothetically, a 12 kW burst lasts 3 minutes while nothing else runs. Over a 15-minute interval it averages 2.4 kW (12 x 3 divided by 15). Over a 60-minute interval it averages 0.6 kW (12 x 3 divided by 60). The longer the interval, the more a short overlap is diluted; the shorter it is, the more a half-hour of stacking costs.

The hours that count. Some demand charges apply to the highest interval at any hour. Others apply only to intervals inside defined peak hours, and some tariffs, like LG&E’s, have both. Los Alamos said its demand “is measured independently of Time-of-Use (TOU) peak and off-peak hours,” so a midnight peak counts as much as a 6 p.m. one.

Look-back provisions. Some tariffs carry a high demand forward into later months, an arrangement usually called a ratchet. LG&E’s and KU’s residential RTOD-Demand sheets, as checked, contain no such provision: each month’s charge depends on that month’s intervals.

Tariff Interval Hours that count Price per kW per month
LG&E RTOD-Demand (Kentucky) 15 minutes Base: all hours. Peak: 1 to 5 p.m. EST on weekdays April to October; 6 to 10 a.m. and 6 to 10 p.m. EST on weekdays November to March $4.32 base, $9.46 peak
KU RTOD-Demand (Kentucky) 15 minutes Same as LG&E $4.20 base, $10.81 peak
Los Alamos County residential demand (New Mexico), as described before its start 60 minutes All hours, independent of TOU periods $1.00

Sources: LG&E and KU tariff Sheets No. 7 and 7.1, effective with service on and after September 1, 2026, checked November 22, 2026; Los Alamos County Utilities page, read from an archived copy dated April 21, 2026, which said the structure would begin “no sooner than July 2026.”

The Los Alamos page gave a sense of scale: a 2025 study for the utility estimated average residential peak demand at about 7 kW, which at $1.00 per kW would be a $7.00 monthly demand charge. At LG&E’s prices, the same 7 kW inside peak hours would cost $96.46 (7 x $13.78). The word “demand charge” covers very different amounts of money.

How a demand charge differs from a time-of-use price

A time-of-use energy rate and a demand rate both reward timing, but they punish mistakes very differently.

Time-of-use energy rate Demand rate
What is priced Each kWh, at the price of its rating period Each kWh at a lower price, plus the month’s highest interval in kW
Cost of one bad hour The extra price on that hour’s kWh only Can set the demand charge for the whole month
What helps Moving kWh out of peak hours Keeping loads apart, and out of peak hours
What a battery does Supplies peak-hour kWh Caps the grid draw in the worst interval, up to its kW rating
Information needed kWh by hour kW by interval, at the tariff’s interval length

Suppose a dryer run uses 4 kWh. Run in the evening peak on LG&E’s RTOD-Energy rate, it costs about 40 cents more (4 x $0.09995). On RTOD-Demand, the same run on top of the car and the oven can set a peak charge of more than $100 for the month.

A real residential demand rate: LG&E and KU RTOD-Demand

LG&E and KU’s Residential Time-of-Day Demand Service is an optional rate that trades a lower energy charge for two demand charges. Its prices, from the tariff sheets in effect since September 1, 2026 (base charges before adjustment clauses and taxes):

Charge LG&E RTOD-Demand KU RTOD-Demand Compare: standard Rate RS
Basic Service Charge $0.48 per day $0.58 per day Same daily charge
Energy charge $0.06427 per kWh $0.05725 per kWh LG&E $0.11499; KU $0.11396
Base demand, highest 15-minute kW at any hour $4.32 per kW $4.20 per kW None
Peak demand, highest 15-minute kW in peak hours $9.46 per kW $10.81 per kW None

Sources: LG&E tariff Sheets No. 5 and 7 and KU tariff Sheets No. 5 and 7, checked November 22, 2026.

“Base” covers all hours. “Peak” covers the same windows as the energy version of the rate, set in Eastern Standard Time all year: 1 to 5 p.m. on weekdays from April through October (2 to 6 p.m. on a daylight-time clock), and 6 to 10 a.m. and 6 to 10 p.m. on weekdays from November through March. Weekends have no peak hours, and a legal holiday on a weekday counts as a weekday. Read together, the sheets bill your highest 15-minute interval of the month at the base price, and your highest 15-minute interval inside peak hours at the peak price. An interval that is the month’s highest and falls in peak hours is billed twice, at $13.78 per kW on LG&E’s rate. If you are unsure how your own bill applies the two charges, the utility can confirm it.

The rate has the same eligibility limits as the energy version. It needs an AMI meter, it is capped at 500 customers on RTOD-Energy and RTOD-Demand combined, first come, first served, and a customer who returns to Rate RS may not come back for 12 months. Customers on it cannot use the company’s Budget Payment Plan (Sheet No. 7.2).

The utilities’ own time-of-day page describes the idea plainly: “don’t use your dishwasher, run a load of laundry and cook dinner at the same time.” When checked in November 2026, that page still listed earlier prices, such as $0.06292 per kWh for LG&E. The tariff sheets are the record; our guide to reading an electric rate schedule explains how to confirm which sheet is in force.

How much demand a month can carry

The energy discount is what pays for the demand charges. On LG&E, RTOD-Demand’s energy charge is 5.072 cents per kWh below Rate RS ($0.11499 minus $0.06427); on KU, 5.671 cents ($0.11396 minus $0.05725). The daily charge is the same on both rates, so the demand rate costs less only when:

base kW x base price + peak kW x peak price is less than monthly kWh x energy discount.

The table works that out for hypothetical months on LG&E’s prices, before riders and taxes.

Monthly kWh Room for demand charges (kWh x $0.05072) Highest kW if base and peak are equal Base kW allowed if peak is held to 3.0 kW
600 $30.43 2.21 kW Not possible (peak alone costs $28.38, and base can never be lower than peak)
900 $45.65 3.31 kW 4.0 kW
1,200 $60.86 4.42 kW 7.5 kW
1,500 $76.08 5.52 kW 11.0 kW

The arithmetic for the 1,200 kWh row: 1,200 x $0.05072 = $60.86. If one interval sets both charges, each kW costs $13.78, and $60.86 divided by $13.78 is 4.42 kW. If peak-hours demand is held to 3.0 kW ($28.38), the remaining $32.48 covers $32.48 divided by $4.32, or 7.5 kW of base demand.

A demand rate therefore favors homes that use a lot of energy at a steady pace, and it is unforgiving of peaks inside peak hours: in a 1,200 kWh month, a single 15-minute interval of 4.5 kW in the 6 to 10 p.m. window, if it is also the month’s highest, uses up the whole discount.

Which household habits set the monthly peak

The monthly peak is set by whichever loads happen to overlap in one interval. Large loads matter most, and in most homes they are the ones that heat something or move a car.

The power a device can draw is printed on it. The Department of Energy’s guide to estimating appliance energy use (an archived copy dated June 2025, as the page no longer loads at its address) notes that “the wattage listed is the maximum power drawn by the appliance,” and that where only amps are listed you can multiply amps by volts.

Load Power it can draw Where the number comes from When it tends to run
Level 2 EV charger Up to 7.2 kW at 30 A for most residential units; Level 2 ranges from 2.9 to 19.2 kW DOE Alternative Fuels Data Center On arrival home, often 5 to 7 p.m.
Electric dryer Read the nameplate; suppose 5 kW for this article’s examples Nameplate Evenings and weekends
Electric oven or range Read the nameplate Nameplate Dinner time
Electric tank water heater Read the nameplate; suppose a 4.5 kW element Nameplate After showers and dishwashing
Heat pump electric backup (heat strips) Read the air handler nameplate; suppose 10 kW Nameplate Cold mornings, defrost, recovery from setbacks
Heat pump or air conditioner compressor Read the outdoor unit nameplate Nameplate Afternoons in summer, mornings and evenings in winter

The suppose values are hypothetical sizes for this article’s examples, not typical figures. The appliance energy cost calculator turns a nameplate wattage into kWh and cost by rate window.

The EV charger: often the largest kW in the house

The Alternative Fuels Data Center notes that Level 2 equipment can operate at 40 to 80 A, beyond the 30 A typical of homes. At 240 volts, 40 A is 9.6 kW and 48 A is about 11.5 kW.

Hypothetically, if a household’s base demand is set by the car charging at night, raising the charging current from 30 A to 48 A adds about 4.3 kW (11.5 minus 7.2) and, at LG&E’s base price, about $18.58 a month (4.3 x $4.32). Two EVs that start charging together double the problem.

The three stacks that set most peaks

On LG&E’s and KU’s rating periods, three overlaps are the usual culprits:

  1. The winter evening stack. The car is plugged in on arrival, dinner goes in the oven, a load of laundry goes in the dryer, and the heat pump is running, all inside the 6 to 10 p.m. EST peak window.
  2. The cold morning stack. A thermostat recovering from a night setback calls for backup heat while the water heater reheats after showers, inside the 6 to 10 a.m. EST window. Hypothetically, a 10 kW strip heater running through one 15-minute interval in that window adds 10 x $13.78 = $137.80 to the month’s bill at LG&E’s prices. Our article on heat pump auxiliary heat explains why strips run and how to keep them off.
  3. The summer afternoon stack. Air conditioning at full load during the 1 to 5 p.m. EST peak (2 to 6 p.m. by the clock), plus a dryer or an early charge for the car.

One month, stacked and staggered

The figure shows one weekday evening for a fictional household, two ways. The household and its load numbers are invented; the prices are LG&E’s published base charges.

Fifteen-minute demand on two fictional January weekday evenings, 5 to 11 p.m.The shaded band is the winter peak window, 6 to 10 p.m. Eastern Standard Time. On the stacked evening the EV charger, oven, dryer and heat pump overlap and the highest 15-minute average reaches 14.0 kW at 6:15 p.m., inside the peak window. On the staggered evening dinner is cooked before 6 p.m., the dryer runs another day and the EV starts at 10 p.m. at a lower current, so the peak-window maximum is 3.0 kW and the evening maximum is 5.0 kW after 10 p.m.Stacked evening (fictional): highest interval 14.0 kW at 6:15 p.m.0 kW5 kW10 kW15 kW14.0 kWStaggered evening (fictional): 3.0 kW in the peak window, 5.0 kW after 10 p.m.0 kW5 kW10 kW15 kW5.0 kW5 p.m.6 p.m.7 p.m.8 p.m.9 p.m.10 p.m.11 p.m.Peak hours for the peak demand charge (6 to 10 p.m. EST)
Example (fictional) 15-minute demand for one January weekday evening, before and after staggering loads. Peak window from LG&E tariff Sheet No. 7.1 (6 to 10 p.m. EST, November to March), checked November 22, 2026.

Example (fictional). A Louisville household with a heat pump, an electric dryer, an electric oven, an electric water heater and one EV uses 1,200 kWh in a 30-day January bill.

On the stacked evening, the car starts charging at 7.2 kW at 6 p.m. while the oven, the dryer and the heat pump are running. The 15-minute interval that starts at 6:15 p.m. averages 14.0 kW. It is the highest interval of the month and it falls in peak hours, so it sets both demand charges.

  • Energy: 1,200 kWh x $0.06427 = $77.12
  • Base demand: 14.0 kW x $4.32 = $60.48
  • Peak demand: 14.0 kW x $9.46 = $132.44
  • Basic Service Charge: 30 days x $0.48 = $14.40
  • Total: $284.44

On staggered days, dinner is cooked before 6 p.m., the dryer runs on a weekend afternoon, and the car starts at 10 p.m. with its charging current set to 16 A, about 3.84 kW at 240 volts (16 A x 240 V). The water heater reheats at 3 a.m., after the car has finished, and the thermostat holds a steady temperature overnight so backup heat stays off in the morning window. The highest interval in peak hours all month is 3.0 kW; the highest at any hour is 5.0 kW, when the car charges alongside about 1.2 kW of heat pump and household load.

  • Energy: 1,200 kWh x $0.06427 = $77.12
  • Base demand: 5.0 kW x $4.32 = $21.60
  • Peak demand: 3.0 kW x $9.46 = $28.38
  • Basic Service Charge: $14.40
  • Total: $141.50

On Rate RS, the same month costs 1,200 kWh x $0.11499 = $137.99, plus $14.40, for $152.39, however the loads are timed. Staggered, the demand rate is $10.88 cheaper. If the household staggers its loads every day but one, and that one evening looks like the stacked chart, the bill is the stacked one: $284.44, or $132.06 more than Rate RS.

One fictional January bill of 1,200 kWh priced four ways at LG&E base chargesRate RS costs $152.39: $137.99 of energy and $14.40 of Basic Service Charge. RTOD-Energy with 20 percent of use on-peak costs $150.13. RTOD-Demand costs $141.50 when the household keeps peak-hours demand at 3.0 kW and base demand at 5.0 kW, and $284.44 when one stacked evening sets both at 14.0 kW: $77.12 energy, $60.48 base demand, $132.44 peak demand and $14.40 Basic Service Charge.Energy chargeBase demandPeak demandBasic Service Charge$0$100$200$300Rate RS$152.39RTOD-Energy, 20% on-peak$150.13RTOD-Demand, staggered$141.50RTOD-Demand, one stacked evening$284.44
Example (fictional) January bill of 1,200 kWh, 30 days, priced on LG&E Rate RS, RTOD-Energy (with 20% of use on-peak, for comparison) and RTOD-Demand, base charges before adjustment clauses and taxes. Source: LG&E tariff Sheets No. 5, 6 and 7, effective September 1, 2026, checked November 22, 2026.

On RTOD-Energy, the staggered household with 20% of its kWh (240 kWh) on-peak would pay 240 x $0.19307 plus 960 x $0.09312, or $135.73, plus $14.40: $150.13. The demand rate rewards the discipline more, and punishes a lapse far more.

Summer months are tighter, because they usually carry fewer kWh to earn the discount.

Example (fictional). The same household uses 1,000 kWh in a 30-day July bill. With habits unchanged, the air conditioner and household loads reach 4.5 kW during the 1 to 5 p.m. EST peak, and the car charging overnight at 7.2 kW alongside about 1.2 kW of other load sets base demand at 8.4 kW.

  • Energy: 1,000 kWh x $0.06427 = $64.27
  • Base demand: 8.4 kW x $4.32 = $36.29
  • Peak demand: 4.5 kW x $9.46 = $42.57
  • Basic Service Charge: $14.40
  • Total: $157.53, against $114.99 + $14.40 = $129.39 on Rate RS, or $28.14 more

With pre-cooling finished before 2 p.m. on the clock, the peak-hours maximum falls to 3.0 kW, and with the car at 16 A, base demand falls to 5.0 kW. The bill becomes $64.27 + $21.60 + $28.38 + $14.40 = $128.65, just $0.74 below Rate RS. The 1,000 kWh month leaves $50.72 of room for demand charges (1,000 x $0.05072), and even a well-managed month uses almost all of it.

How to keep demand low

Keeping demand low means making sure no single interval holds several large loads at once, and that the largest loads run outside peak hours. These are the levers, roughly in order of how much they usually change and how little they cost:

  1. Run one large load at a time. The dryer, the oven, the water heater and the car each run fine on their own. The bill rises when they overlap. Delay-start timers on dryers and dishwashers are the simplest tool.
  2. Move the largest loads out of peak hours. The peak charge is the bigger one: $9.46 per kW on LG&E’s rate against $4.32 for base hours. A load moved from 6 p.m. to 10:30 p.m. still counts toward base demand, but no longer toward peak demand.
  3. Lower the EV charging current. Charging power is roughly volts times amps. At 240 volts, 30 A is 7.2 kW and 16 A is 3.84 kW. The car takes the same kWh either way, but at the lower current an 11.1 kWh charge takes about 2.9 hours (11.1 divided by 3.84) instead of about 1.5 (11.1 divided by 7.2). Where the charger or the car allows a lower limit, it is the cheapest change on this list.
  4. Keep backup heat off in the morning window. A large overnight setback asks a heat pump for a hard recovery at 6 a.m., and some thermostats bring on backup heat to speed a recovery. A steadier overnight setting, or a recovery finished before 6 a.m. EST, avoids the most expensive interval of the winter.
  5. Use load management. Some equipment pauses one load, often the EV charger, while another runs; RMI’s 2015 review describes Black Hills Power customers’ controllers that cycle appliances “on and off in 15-minute cycles.” Whether such equipment fits a given panel is a question for a licensed electrician, and our article on EV charger amps and your panel covers when load management is used in place of a service upgrade.
  6. Let a battery cap the grid draw. A home battery can supply part of a load so the grid sees less, within the limits of its kW rating, its charge and its backup reserve.

The software side of these levers is scheduling: deciding, for each day, when each large load runs so that two never share an interval. Culni is a software company that reads a home’s electricity rate and runs one daily schedule across rooftop solar, a home battery, EV charging and flexible loads, then checks the result against the bill each month. Its rate engine records demand charges along with energy prices, so that on a demand rate the schedule keeps large loads such as the car, the dryer and battery grid charging from running at the same time; flexible loads covers how water heaters, heating and cooling, and appliances are timed. Which devices in a given home can be scheduled is confirmed home by home.

Setting a kW budget for each window

Choose a kW budget for peak hours and another for the rest of the day, then decide which loads get it first. In a 1,200 kWh month on LG&E’s prices, holding peak hours to 3.0 kW leaves room for about 7.5 kW of base demand.

Priority Load Peak-hours rule Base-hours rule
1 Heating or cooling for comfort and health, medical equipment Always runs; keep backup heat off by avoiding deep setbacks Always runs
2 Cooking Runs when needed; avoid overlapping with any other large load Runs when needed
3 Water heating Heat before the window opens; hold during it One element at a time, never with the car
4 EV charging Never in peak hours unless the car must leave Reduced current, after the other loads finish
5 Dryer, dishwasher, pool pump Never in peak hours Delay-start, one at a time

The order is a judgment; comfort and medical needs should never be traded for a demand charge. What matters is that the rule is carried out every day by timers, settings or a schedule, because the month’s bill is set by the one day it was not.

Batteries and solar on a demand rate

A battery lowers demand only when it is charged, set to discharge at the right moment, and powerful enough for the gap. Its inverter’s power rating caps how much it can take off any interval. The fictional example home on this site has a 5 kW battery, so it could cut a 14.0 kW interval to no less than 9.0 kW, and only if it had energy above its backup reserve at 6:15 p.m. On LG&E’s winter schedule, the battery also has to cover two peak windows a day from one charge.

Grid charging can raise demand. A battery charging from the grid at night adds its charging power to every interval it charges in. Hypothetically, a 5 kW charge rate that sets the month’s base demand costs 5 x $4.32 = $21.60 on LG&E’s rate. A schedule on a demand rate should charge slowly, or charge from solar, and never alongside the car. Whether grid charging is allowed at all depends on the battery’s settings and the interconnection agreement; battery scheduling explains how a schedule works inside those limits.

Solar lowers kWh but may not lower demand. RMI’s 2015 review describes a home with rooftop solar and an EV whose “net grid demand surges from essentially zero to peak” when the sun sets and the car is plugged in. On LG&E’s winter schedule, both peak windows fall at hours of weak or no sunlight, so solar alone does little for the winter peak charge. In summer, the 1 to 5 p.m. EST window overlaps strong production, and solar can lower peak-hours demand on clear afternoons; a passing cloud during one interval is enough to set the month’s figure.

Who a demand rate suits, and who should avoid one

A demand rate suits a household that uses a fair amount of energy, can keep its large loads apart, and can keep them out of peak hours with timers or a schedule rather than daily attention. It does not suit a household whose big loads are tied to fixed routines, or one where nobody will notice a stacked evening until the bill arrives.

Household Fit for a rate like RTOD-Demand Why
EV owner who can charge after 10 p.m. at a reduced current Good High kWh earns the energy discount; the car adds only base demand
All-electric home with a heat pump, no backup heat in use, timers on dryer and water heater Possible Depends on cold mornings; one strip-heat interval in the peak can erase the month’s discount
Heat pump with frequent strip heat on cold mornings Poor The morning window is where strips run
Small home with low monthly kWh Poor Little energy to earn the discount; at 600 kWh a month, a 3.0 kW peak alone uses it up
Home with a battery set to cap grid draw Possible Limited by the battery’s kW rating, its charge and its reserve
Large family with fixed dinner, laundry and charging times Poor unless automated Stacking is the default

How to check a demand rate against your own usage

You can test a demand rate before you switch, but you need interval data, not monthly totals. EIA reports that about 73% of US residential meters were advanced (AMI) meters in 2022, recording usage at least hourly. Some utilities offer 15-minute data; ask for the same interval your tariff bills on.

  1. Download 12 months of interval data, ideally at the tariff’s interval. If you only have hourly data and the tariff uses 15 minutes, treat each hourly figure as a floor: the real 15-minute peak can be higher, as the stacked evening shows: its 6 to 7 p.m. hour averages 12.3 kW while its highest 15 minutes reach 14.0 kW.
  2. Mark the peak hours for each date in the tariff’s clock (Eastern Standard Time for LG&E and KU) and season.
  3. Find each month’s highest interval overall and its highest interval in peak hours. A spreadsheet’s maximum function over the right rows does this.
  4. Price each month on both rates. Energy at each rate’s price, the two demand charges on the demand rate, and the daily charge on both.
  5. Look at the worst months, not the average. A demand rate that saves in eight months and loses heavily in two cold ones may lose for the year.
  6. List what you would change (charger current, timers, thermostat settings, battery mode) and reprice the months they would affect.
  7. Check the terms: the enrollment cap, the meter requirement, the 12-month return rule and the loss of budget billing.

Converting interval kWh into kW

Interval files usually report energy, not power: the kWh used in each interval. To get the average kW for an interval, divide its kWh by the interval’s length in hours. For 15-minute data, that means multiplying by 4: an interval showing 3.5 kWh averaged 14.0 kW. For hourly data, the kWh figure and the average kW are the same number. Getting this step wrong understates a 15-minute peak by a factor of four, which would make any demand rate look far cheaper than it is.

In a spreadsheet, the monthly maximum of the kW column gives base demand, and the same maximum over peak-hours rows gives peak demand. The home energy glossary defines kW, kWh and demand charge in one place.

Questions to ask the utility before switching

Before moving to a demand rate, ask the utility:

  1. Which interval is billed, 15 or 60 minutes, and can you download your usage at that interval?
  2. How the two charges apply. On LG&E’s and KU’s RTOD-Demand, confirm that base demand is the highest interval at any hour and peak demand the highest interval in peak hours, as the sheets read.
  3. How a solar home is measured. LG&E’s sheet bills “the average kW demand delivered to the Customer,” which reads as power flowing from the grid into the home; ask how exports and self-used solar are treated.
  4. Whether a place is open under the 500-customer cap, which covers both time-of-day rates together.

Keep the answers with the date and the source.

What to do next

  • Read your tariff for any rate with a charge per kW, and note its interval, its hours and its price.
  • Read the nameplates on your EV charger, dryer, oven, water heater and heat pump air handler, and write down each one’s kW.
  • Find your stacks. Look for the times of day when two or more of those loads run together, especially inside peak hours.
  • Set the habits up as settings, not intentions: a lower charging current, a later charging start, delay-start timers, a steady overnight thermostat.

If you would like a demand rate checked against your own interval data and devices, you can send your rate plan and a recent bill, and the home energy plan will show every assumption behind the comparison.

TodayYour turn

Want this worked out for your home?

Send your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan and every assumption behind it.

Remote. No site visit needed.