Why your heat pump bill jumps in winter: auxiliary heat strips explained

Heat pump auxiliary heat high bill? Why strips run, the balance point, settings that waste power, what strips cost on time-of-day and demand rates, and fixes.

Reader question
Why is my electric bill so high in winter with a heat pump, and how do I stop the backup heat strips from running more than they should?
An enamel picture of a snowed-in log cabin at night with a thin curl of chimney smoke beside a woodpile burned down to a few last logs.

A heat pump bill jumps in winter for two reasons. The house needs more heat as the outdoor temperature falls, and the heat pump delivers less heat, less efficiently, the colder it gets, so electric resistance heat strips switch on to fill the gap at about one unit of heat per unit of electricity. Some strip use is normal below the balance point and during defrost. Strips that run on mild days, after a large thermostat jump, in emergency heat mode or because of a missing outdoor lockout are waste, and most of it can be fixed with thermostat settings and a technician visit.

This guide explains how the two kinds of strip use differ, how to spot the wasteful kind in your thermostat reports and smart meter data, and what it costs on a real bill. It prices strip heat on LG&E’s standard residential rate and its two time-of-day rates in Kentucky, where winter peaks fall at 6 to 10 a.m. and 6 to 10 p.m., right when a cold house is warming up.

Two reasons a heat pump bill rises in winter

A winter bill rises partly because of the weather and partly because of how the heat gets made. Separating the two tells you whether there is anything to fix.

The first reason is the heating load. A house loses heat roughly in proportion to the difference between indoor and outdoor temperature, so a 20°F day needs far more heat than a 45°F day. That part of the bill follows the weather, and every heating system faces it.

The second reason is the heat source. A heat pump moves heat from outdoor air into the house and delivers more heat than the electricity it uses. ENERGY STAR says an air-source heat pump can deliver up to three times more heat energy than the electrical energy it consumes. Heat strips, by contrast, turn one kWh of electricity into one kWh of heat. Every hour the strips carry the load instead of the compressor makes the same heat cost several times as much; the published comparisons below range from 2 to 5 times.

Example (fictional). A house uses 900 kWh in October and 2,100 kWh in January. Of January’s extra 1,200 kWh, suppose 800 kWh is the heat pump working harder in colder weather and 400 kWh is strip heat. If half of that strip heat ran on mornings after a large thermostat setback, removing it would cut about 200 kWh of strip electricity. The heat pump would supply the same heat with roughly 200 / 2.5 = 80 kWh at an assumed coefficient of performance of 2.5, a saving of about 120 kWh. At LG&E’s Rate RS energy charge of $0.11499 per kWh, that is about $13.80 for the month before riders and taxes.

The example shows the scale. Strip waste rarely explains the whole jump, but it can be a meaningful slice of it, and it is the part you can change.

How a heat pump and its heat strips share the work

A heat pump system with electric backup has two heat sources in one air handler: the compressor-driven heat pump and a bank of resistance strips. The thermostat decides which runs. Most confusion about winter bills comes from four terms that sound alike.

Term What it is When it should run
Heat pump (stage 1, sometimes stage 2) The compressor moving heat from outdoor air Whenever it can meet the load
Auxiliary heat (aux) The strips, brought in automatically to help the heat pump Below the balance point, during defrost, or when the room is well below setpoint
Emergency heat (em heat) The strips alone, with the heat pump locked out, chosen manually Only when the heat pump has failed or is being serviced
Defrost The heat pump briefly reverses to melt frost off the outdoor coil Automatically in cold, damp weather; strips may run to temper the air

Santee Cooper’s Heat Strips 101 (January 13, 2026) describes strips as working “much like a large space heater inside your HVAC unit” and notes that they “draw a large amount of power from the moment they turn on.” Alabama Power’s explainer says a large majority of heat pumps have them, though some systems use a gas furnace as the backup instead (Alabama Power, December 16, 2024). The furnace version, called dual fuel, is controlled differently and is not the subject of this guide.

How big the strips are

Alabama Power’s HVAC specialist says heater kits come in 5 kW increments and gives typical sizes: about 5 kW with a 2-ton system, potentially 10 kW with a 3-ton system, and likely 15 kW with a 4- or 5-ton system. When a 10 kW kit switches on, it adds 10 kW to whatever the home is already drawing, in one step.

Strip kits that come on in stages

A strip kit does not always switch on all at once. If a larger kit is wired in stages, the controls can bring in one 5 kW section and add the next only if the room keeps falling behind. Whether yours is staged, and what triggers the second stage, is a question for the installer, and it matters for two reasons. Each stage held off is several kW that never shows up as a demand spike, and a first stage that is enough on most cold mornings means the full kit runs only on the coldest nights.

Staging does not make strip heat cheaper per kWh. A 5 kW stage running two hours and a 10 kW kit running one hour both turn 10 kWh of electricity into 10 kWh of heat. What changes is the kW, which matters on a rate with a demand charge.

How much more strip heat costs

The published comparisons agree on the direction and differ on the number. Alabama Power says strips consume approximately three to four times the energy a heat pump uses for the same heat. Google’s Nest help page says auxiliary heat can cost about 2 to 5 times as much as running the heat pump. Part of the spread is outdoor temperature: a heat pump’s efficiency falls as it gets colder, so its advantage over strips is largest in mild weather and narrows near its lower limit.

The balance point: when strips are supposed to run

The balance point is the outdoor temperature at which the heat pump’s output exactly matches the house’s heat loss. Above it, the heat pump can carry the house alone, and strips should not be needed except during defrost or a recovery. Below it, the heat pump runs continuously and the strips make up the difference.

Two lines cross to make the balance point. The house’s heat loss rises as it gets colder outside. The heat pump’s capacity falls as it gets colder, because there is less heat in the outdoor air to move. Where the falling line meets the rising one is the balance point, and it is specific to each house and each heat pump.

Balance point: house heat loss against heat pump capacity by outdoor temperatureHypothetical house losing 600 Btu per hour for each degree below 65°F, so 36,000 Btu per hour at 5°F. A standard heat pump rated 30,000 Btu per hour at 47°F falls to 13,200 at 5°F and meets the house's loss at about 28°F. A cold-climate heat pump with the same 47°F rating keeps 70 percent, 21,000 Btu per hour, at 5°F and meets the loss at about 23°F. Below each balance point the strips supply the gap; at 5°F that gap is about 6.7 kW for the standard unit and 4.4 kW for the cold-climate unit.010,00020,00030,00040,000Btu per hourStrips fillthe gap5°F17°F35°F47°F65°FOutdoor temperatureHouse heat lossStandard heat pump (balance about 28°F)Cold-climate heat pump, 70% at 5°F (balance about 23°F)
Hypothetical house and heat pumps, straight-line capacities for illustration. The 70 percent capacity retention at 5°F is the ENERGY STAR cold-climate criterion; real capacity curves come from the manufacturer's data or the NEEP cold-climate product list.

Example (fictional). A house loses 600 Btu per hour for every degree the outdoor temperature is below 65°F. Its standard heat pump delivers 30,000 Btu per hour at 47°F and 18,000 at 17°F, a loss of 400 Btu per hour per degree.

  • Balance point: heat loss 600 x (65 - T) equals capacity 18,000 + 400 x (T - 17). Solving gives 39,000 - 600T = 11,200 + 400T, so T = 27.8°F.
  • At 17°F: loss 600 x 48 = 28,800 Btu per hour; capacity 18,000; gap 10,800 Btu per hour, which is 10,800 / 3,412 = 3.2 kW of strips.
  • At 5°F: loss 36,000; capacity 18,000 - 400 x 12 = 13,200; gap 22,800 Btu per hour, or 6.7 kW of strips.
  • Above 28°F, the heat pump can carry the house by itself. Strips running on a 40°F morning are not covering a capacity shortfall; something else is calling them.

Lowering the heat loss line

The balance point moves when either line moves. A better heat pump raises the capacity line; a tighter house lowers the heat loss line. Alabama Power’s specialist puts it simply: improving the energy efficiency of the home “will always reduce energy consumption.”

Example (fictional). The same house after air sealing and attic insulation loses 500 Btu per hour per degree instead of 600.

  • New balance point: 500 x (65 - T) = 18,000 + 400 x (T - 17), so 32,500 - 500T = 11,200 + 400T, and T = 23.7°F, about 4°F lower than before.
  • Strips needed at 17°F: loss 500 x 48 = 24,000 Btu per hour against 18,000 of capacity, a gap of 6,000 Btu per hour or 1.8 kW, down from 3.2 kW.
  • Strips needed at 5°F: 30,000 - 13,200 = 16,800 Btu per hour, or 4.9 kW, down from 6.7 kW.

Envelope work lowers the bill twice: the heat pump has less heat to supply in every hour, and the strips have a smaller gap to fill in the coldest ones. Which measures fit a particular house is a question for an energy auditor or a qualified contractor.

What cold-climate ratings tell you

ENERGY STAR’s cold-climate criteria require a heat pump to deliver at least 70% of its 47°F heating capacity at 5°F, with a coefficient of performance of at least 1.75 at 5°F. A unit that meets those numbers keeps far more capacity in a cold snap, which pushes the balance point down and shrinks the gap the strips must fill. In the chart, the cold-climate unit with the same 47°F rating balances at about 23°F and needs about 4.4 kW of strips at 5°F instead of 6.7 kW.

The usual efficiency rating does not show this. The Northeast Energy Efficiency Partnerships (NEEP) notes that the standard heating rating does not include test points below 17°F. NEEP’s cold-climate list reports standardized low-temperature performance data, which is where an installer can find capacity and efficiency at 17°F and 5°F for a listed model.

Where strip use is normal

Strip heat is expected in three situations: below the balance point, when the heat pump cannot keep up; during defrost, when the system briefly reverses and strips can temper the air (Google’s Nest help page lists defrost as one of the times auxiliary heat turns on); and when the heat pump has failed. Santee Cooper says it is common for strips to activate when outdoor temperatures are anywhere from 32°F to 40°F, depending on thermostat settings and the heat pump, so on many systems the settings, not the weather, decide where strips start.

Five causes of strip heat you do not need

When strips run above the balance point outside defrost, look first at settings and faults. These five come up in utility and manufacturer guidance.

1. Large thermostat jumps and setback recovery

Thermostats bring in auxiliary heat when the room falls too far below the setpoint. Alabama Power puts that trigger at about 1.5 to 2 degrees: with the room at 62°F and the thermostat set to 70°F, the strips engage regardless of the weather. Santee Cooper’s advice is to increase the temperature by no more than one or two degrees at a time, because “large temperature jumps can signal your system to activate heat strips unnecessarily.”

That makes deep overnight setbacks expensive with a heat pump. The morning recovery creates exactly the large gap that calls the strips. Google’s installer guide notes that Nest thermostats use a fixed 1°F droop (how far the room may fall below the setting before more heat is called), which shows how small the trigger can be (Nest heat pump configuration guide).

2. Emergency heat left on

Emergency heat runs the strips alone and locks out the heat pump. Alabama Power says it should be turned on manually “only when the heat pump is not functioning properly.” The Nest installer guide notes that emergency heat is off by default. If someone switched to emergency heat during a cold snap or a service call and never switched back, every hour of heating since then has run on strips.

3. No outdoor lockout, or one set too high

An auxiliary heat lockout stops the strips from running above a chosen outdoor temperature. Without one, or with one set high, the thermostat can call strips on mild days whenever the room lags. The Nest guide lists an auxiliary heat lockout with a default of 40°F and a range from 0 to 90°F, and a compressor lockout with a default of -25°F. Its Heat Pump Balance feature, which sets the lockout automatically, defaults to Max Comfort, described as using auxiliary heat more to reach setpoints faster; Max Savings uses it less. Other thermostat makers use different names for similar settings.

Where to set the lockout depends on the heat pump’s capacity at low temperatures and on the house, which is why it belongs with the installer. A lockout set below the balance point can leave the house short of heat on the coldest days.

4. A thermostat set up or wired for the wrong equipment

A heat pump thermostat needs to know which wire calls the compressor, which calls the reversing valve, and which calls the strips. The Nest guide’s wiring table assigns auxiliary heat to the W2/AUX terminal and emergency heat to a separate terminal, and asks the installer to choose “single fuel” for a heat pump with strips. A thermostat configured as a conventional furnace, or with the strip wire on the first heating stage, can bring on strips with every call for heat. Diagnosing wiring is work for a licensed HVAC technician.

The same guide notes that Nest thermostats read the outdoor temperature from local weather data over Wi-Fi and do not support an outdoor sensor; without Wi-Fi, they decide when to use auxiliary heat from system performance instead. A thermostat that has lost its connection may stage strips differently than you expect.

5. A heat pump that has lost capacity

Anything that cuts the heat pump’s output pushes more of the load onto the strips: a clogged filter, an outdoor coil blocked by leaves or snow, a defrost control that is not working, low refrigerant, or poor airflow through leaky ducts. Alabama Power’s advice is to keep the system running at peak performance and to improve the home’s efficiency, because both reduce strip use. A system that ran fine last winter and now runs strips at 35°F deserves a service call.

How to tell whether your strips run too much

You can check strip use from three places: the thermostat display, the thermostat’s runtime reports, and your smart meter’s interval data. Used together, they show both how often strips run and when.

The thermostat display and reports

Many heat pump thermostats show an indicator such as “Aux heat” or a second stage while strips run; Alabama Power describes a display showing “Stage 1 & 2” when strips assist the heat pump. Connected thermostats may also keep daily runtime reports. ENERGY STAR’s criteria require certified smart thermostats to report electric resistance heat use for heat pump installations, so a certified model should show auxiliary runtime separately.

Look at auxiliary runtime alongside outdoor temperature. Strip hours on days well above your balance point suggest a setting or a fault.

Reading 15-minute smart meter data

If your utility offers 15-minute or hourly usage, strip heat leaves a clear signature, because a strip kit adds several kW in one step. To convert a 15-minute reading to average kW, multiply the kWh by four.

What the data show Likely cause What to check
A 2 to 3 kWh spike in one 15-minute interval at the same time each morning, on mild days Setback recovery calling strips Shrink the setback or recover in 1°F steps
Higher use at every heating call, even above 40°F Strips on the first heat stage, emergency heat on, or no lockout Thermostat mode and configuration; technician for wiring
Short, regular spikes in cold, damp weather Defrost cycles with strips tempering the air Usually normal; ask about defrost settings if very frequent
Use high around the clock only on the coldest days Below the balance point Expected; consider envelope work or a cold-climate unit later
Gradual rise in strip use compared with last winter at similar temperatures Lost heat pump capacity Filter, outdoor coil, refrigerant, airflow

Example (fictional). A 15-minute reading of 2.9 kWh from 6:15 to 6:30 a.m. on a 42°F morning is an average of 2.9 x 4 = 11.6 kW. The same home’s afternoon readings with the heat pump running are about 0.75 kWh per interval, or 3.0 kW. The difference, about 8.6 kW, matches a 10 kW strip kit cycling partway through the interval, at a temperature where the heat pump should not need help. The 6 a.m. thermostat schedule, which jumps from 62°F to 69°F, is the first thing to change.

Comparing winters fairly

Monthly totals swing with the weather, so compare a month with the same month last year after allowing for how cold each was. Heating degree days, which weather services publish, are a common way to do that: divide the month’s kWh by its heating degree days and compare the ratio between winters. A rising ratio with no change in the household suggests more strip use or lost capacity.

What strip heat costs on your bill

On a flat rate, strip heat costs more energy. On a time-of-day rate, it also costs more per kWh if it runs in peak hours. On a demand rate, a single 15-minute burst can set the demand charge for the whole month. LG&E’s tariff in Louisville has all three versions, which makes it a clear worked case.

On a flat rate

LG&E’s standard residential Rate RS charges $0.11499 per kWh for energy (tariff Sheet No. 5, effective September 1, 2026), base charges before riders and taxes. One hour of a 10 kW strip kit is 10 kWh, or $1.15. The same 10 kWh of heat from the heat pump at an assumed coefficient of performance of 2.5 takes 4 kWh, or $0.46.

On a time-of-day rate

On RTOD-Energy, energy costs $0.19307 per kWh on-peak and $0.09312 off-peak (Sheet No. 6). From November through March, weekday on-peak hours are 6 to 10 a.m. and 6 to 10 p.m. Eastern Standard Time (Sheet No. 6.1), the hours when a house recovers from an overnight setback and when people come home. An hour of 10 kW strips costs $1.93 in those windows and $0.93 outside them.

On a demand rate

On RTOD-Demand (Sheet No. 7), energy is cheaper, $0.06427 per kWh, but the bill adds a base demand charge of $4.32 per kW on the month’s highest 15-minute average demand in any hour, and a peak demand charge of $9.46 per kW on the highest in peak hours (Sheet No. 7.1). Santee Cooper makes the general point: strips “can raise your electric demand,” and if they activate during peak hours they create “a sudden spike in power use.” For how demand charges are measured and managed, see the guide to residential demand charges.

EventRate RSRTOD-EnergyRTOD-Demand
10 kW strips for 1 hour, 7 to 8 a.m. on a winter weekday10 kWh x $0.11499 = $1.1510 kWh x $0.19307 = $1.9310 kWh x $0.06427 = $0.64 in energy, plus the demand effect below
Same heat from the heat pump at an assumed COP of 2.54 kWh = $0.464 kWh = $0.774 kWh = $0.26
Monthly demand charges if that hour sets the month's peak: 14 kW (strips, heat pump and other loads)Not applicableNot applicable14 x ($4.32 + $9.46) = $192.92
Monthly demand charges if the peak stays at 5 kW without stripsNot applicableNot applicable5 x ($4.32 + $9.46) = $68.90
Hypothetical loads. Prices: LG&E tariff Sheets No. 5, 6, 7 and 7.1, effective September 1, 2026 (rating periods and demand definition from the February 16, 2026 sheets), base charges before riders and taxes, checked November 2026. On RTOD-Demand the base charge applies to the highest 15-minute demand in any hour and the peak charge to the highest in peak hours; here one interval sets both.

Over a whole month

Separating needed strip heat from avoidable strip heat shows where the money is.

Example (fictional). A heat pump home on LG&E RTOD-Energy in January.

  • Needed strip heat, on nights below the balance point: 120 kWh, of which 80 kWh falls off-peak and 40 kWh on-peak. Cost: 80 x $0.09312 = $7.45 plus 40 x $0.19307 = $7.72, or $15.17.
  • Avoidable strip heat, from a 62°F to 69°F jump at 6 a.m.: 20 weekday mornings x 10 kW x 0.5 hours = 100 kWh, all in the 6 to 10 a.m. peak. Cost: 100 x $0.19307 = $19.31.
  • The fix: a 1 to 2°F setback and a stepped warm-up finished by 6 a.m. The heat pump makes the same 100 kWh of heat with about 40 kWh at an assumed COP of 2.5, off-peak: 40 x $0.09312 = $3.72. The month’s bill falls by about $15.58 (19.307 minus 3.725) before riders and taxes, without touching the strip heat the house actually needs.

The last two rows of the cost table are the bigger point. On a demand rate, one morning when the strips come on in a peak window can add about $124 to the month ($192.92 minus $68.90), more than all the strip energy in the fictional month above would cost. Whether either time-of-day rate suits a heat pump household is covered in the LG&E and KU time-of-day comparison.

Settings you can change yourself

These changes need no tools and no wiring. They lower strip use without lowering comfort much, and each can be undone.

  1. Raise the temperature 1 to 2°F at a time. Santee Cooper’s guidance. Alabama Power gives the same idea as a walk-up: set 63°F, let the house reach it, then 64°F, and so on.
  2. Shrink or drop overnight setbacks. With a heat pump, a setback of 1 to 2°F, or none, can cost less than a large one followed by a strip-assisted recovery.
  3. Check the mode. Make sure the thermostat is in heat, not emergency heat, unless the heat pump has failed.
  4. Pick the savings-oriented heat pump setting if your thermostat has one, such as Max Savings on a Nest, and watch comfort for a week.
  5. Replace or clean the filter on the schedule the system’s manual gives, and keep leaves, snow and ice clear of the outdoor unit.
  6. Keep supply and return vents open in a ducted system; closing many vents restricts airflow, which can lower what the heat pump delivers.
  7. Schedule the morning warm-up before the peak on a time-of-day rate, in steps, so recovery does not land in the 6 to 10 a.m. window. The guide to pre-heating before peak hours gives a stepped schedule for LG&E’s winter windows.
  8. Watch the thermostat’s auxiliary runtime for two weeks after each change, against the outdoor temperature.

What to ask an HVAC technician

Some fixes belong with a licensed HVAC technician: anything involving wiring, refrigerant, lockout temperatures or the strip kit itself. A focused list makes the visit more useful.

  • Is the thermostat configured as a heat pump with electric auxiliary heat, and are the auxiliary and emergency heat wires on the right terminals?
  • Where does the thermostat get the outdoor temperature, from an outdoor sensor or from weather data over Wi-Fi, and is that working?
  • What is this heat pump’s capacity at 17°F and 5°F, from the manufacturer’s data or the NEEP list, and what is the balance point for this house?
  • Where should the auxiliary heat lockout and the compressor lockout be set for this equipment and house?
  • How many stages does the strip kit have, and can the second stage be held off until the first stage cannot keep up?
  • Is the refrigerant charge correct, and is the defrost control working?
  • Is airflow within the manufacturer’s range, and are there duct leaks in unconditioned space?
  • If the system is near replacement, which cold-climate models fit this house? ENERGY STAR’s cold-climate criteria (70% of capacity and a COP of at least 1.75 at 5°F) and the NEEP list are good starting filters.

One note on incentives: ENERGY STAR’s heat pump page still mentions a federal tax credit of up to $2,000, but the IRS page for the energy efficient home improvement credit limits it to qualifying property placed in service before December 31, 2025, so it does not apply to equipment installed now. Ask a tax professional about your own situation, and check your utility for current programs.

Winter peaks in Kentucky: timing the morning recovery

LG&E and KU set their time-of-day rating periods in Eastern Standard Time all year. Their joint time-of-day page lists the same weekday winter windows for both utilities: 6 to 10 a.m. and 6 to 10 p.m. EST from the first Sunday in November through the second Saturday in March, shifting to 7 to 11 a.m. and 7 to 11 p.m. on the clock in the weeks when daylight time and the winter windows overlap. Weekends are off-peak.

LG&E’s two time-of-day rates are optional, need an AMI meter and are limited to 500 customers across both rates combined (Sheet No. 6). For a heat pump household on either one, the morning window is the expensive one. It begins in the coldest part of the day, it catches any recovery from a night setback, and it is when water heaters and showers add load. Three habits keep strips out of it:

  1. Finish warming the house by 6 a.m., starting 1°F steps from about 4 a.m., with the heat pump alone.
  2. Hold a slightly lower setting through the peak, 1 to 2°F below normal, and let the house drift rather than recover.
  3. Recover after 10 a.m. in steps, when it is off-peak and usually warmer outside, so the heat pump runs more efficiently.

Households on Rate RS pay the same price at every hour, so timing does not change the price per kWh, but the strip rules still apply: every hour of avoidable strip heat costs several times what the same heat costs from the heat pump. The Louisville and Kentucky page gives broader context on the state’s utilities and rates.

Common questions about auxiliary heat

Is it a problem if aux heat comes on at all?

No. Below the balance point, during defrost and when the house has fallen well below its setting, strips are doing their job. The question is whether they run when the heat pump could have carried the load, which you can see by comparing auxiliary runtime with outdoor temperature.

Should I switch to emergency heat when it gets very cold?

No, unless the heat pump has failed. Emergency heat locks out the heat pump, so the strips carry the whole load. Even below the balance point, the heat pump still supplies much of the heat; in the fictional example at 17°F it supplies 18,000 of the 28,800 Btu per hour the house needs. Thermostats can let a heat pump run far colder than people expect: the Nest guide’s default compressor lockout is -25°F.

Will a connected thermostat fix it?

It helps you see the problem, and it may offer lockout and balance settings, but it does not fix a wrong configuration on its own. A certified smart thermostat should report resistance heat use separately; the settings still have to suit the equipment and the house.

Does a bigger strip kit cost more to run?

Not per unit of heat. Every strip kit turns one kWh into one kWh of heat, so a bigger kit delivers the same heat faster. It does raise the kW the home draws while it runs, which matters on a demand rate and for the utility’s winter peak.

Is a dual fuel system different?

Yes. With a gas furnace as backup, the thermostat switches from the heat pump to the furnace at a set outdoor temperature. The Nest guide calls this the dual fuel breakpoint, with a default of 30°F, and notes that the alternate heat never runs at the same time as the heat pump. The cost comparison then depends on gas and electricity prices, not on strip heat.

A checklist and next steps

Use this list once at the start of winter, and again after the first cold snap.

  • Thermostat in heat mode, not emergency heat
  • Overnight setback of 2°F or less, or none
  • Morning warm-up in 1 to 2°F steps, finished before any morning peak window
  • Auxiliary runtime checked against outdoor temperature for two weeks
  • Smart meter 15-minute data checked for strip-sized spikes on mild mornings
  • Filter replaced and outdoor unit clear
  • Technician visit booked for lockout settings, wiring check, refrigerant and defrost if strips run above about 35 to 40°F
  • Balance point and low-temperature capacity noted for the next replacement decision

To price a strip stage yourself, the appliance energy cost calculator turns watts and hours into cost by rate window; its default example, 5,000 watts for one hour 12 times a month, is one 5 kW strip stage, and it costs $18.60 a month at a fictional 31-cent peak price against $4.80 at an 8-cent off-peak price.

Culni is a home energy software company that reads a home’s electricity rate, runs one daily schedule across flexible loads such as a heat pump, and each month compares the estimated bill with the actual one and explains what moved, which is where a run of strip heat would show up. Device connection, including the thermostat, is confirmed home by home. The all-electric homes page describes how heating fits with the water heater and EV on one schedule, and you can send your rate plan, a recent bill and your device list if you want a written home energy plan for your house.