Should you charge your home battery from the grid?

Charging a battery from the grid pays only when the peak price beats the off-peak price after round-trip losses and wear. The break-even test on real tariffs.

Reader question
When does it pay to charge a home battery from the grid at night instead of only from solar, and when does it lose money?
An enamel picture of a hot-air balloon half inflated on a field at dawn, its burner glowing and its basket tethered to the ground.

Charging a home battery from the grid pays only when each kWh it later delivers in the peak is worth more than the grid energy it took to put it there. In numbers: the peak price must be higher than the off-peak price divided by the battery’s round-trip efficiency, plus whatever allowance you make for battery wear. At 85% efficiency, the peak price has to sit at least about 18% above the off-peak price before wear is counted. On a flat rate grid charging always loses money; on a wide time-of-use spread it can earn 8 to 15 cents per kWh delivered on published Kentucky tariffs; and on clear days when solar will fill the battery anyway, it adds nothing.

This article builds that test step by step, runs it on real tariffs checked in November 2026, and then covers the things the price arithmetic leaves out: low-solar winter days, warranty throughput, the names manufacturers give to battery modes, interconnection rules, demand charges and the end of the federal battery tax credit. Prices are base energy charges as published, before riders and taxes, unless a passage says otherwise.

The break-even test for grid charging

Grid charging is worth turning on when the price you avoid at the peak, minus the cost of the grid energy needed to deliver that kWh, minus a wear allowance, is greater than zero. Everything else in this article is a way of finding the four numbers that go into that test.

The four numbers

  1. The peak price you avoid (P peak). The energy charge per kWh in the window when the battery discharges. It comes from your rate schedule, not from your bill’s average price.
  2. The price of the charging energy (P charge). For grid charging, the price in the window when the battery charges, usually off-peak. For solar charging, it is the export credit you give up by storing the kWh instead of sending it out.
  3. Round-trip efficiency (η). The share of the energy put into the battery that comes back out as usable AC power. A battery that takes in 1 kWh and returns 0.85 kWh has a round-trip efficiency of 85%.
  4. A wear allowance (w). A value you assign, in cents per kWh delivered, for the share of the battery’s warranted life that each cycle uses up. It is zero for many owners and matters only in the cases described later.

The formula in one line

Each kWh delivered at the peak needs 1 ÷ η kWh from the grid. So the value of one grid-charged kWh is:

Value per kWh delivered = P peak − (P charge ÷ η) − w

Grid charging pays when that number is positive. Rearranged, the break-even peak price is P charge ÷ η + w.

Why losses raise the bar more than they seem to

An 85% round-trip efficiency sounds like a 15% haircut on the savings. It is really a 17.6% markup on the charging price, because you buy 1 ÷ 0.85 = 1.176 kWh for every kWh you get back. At 90%, the markup is 1 ÷ 0.90 = 1.111, or 11.1%.

Where does the efficiency figure come from? NREL’s Annual Technology Baseline uses 85% as a representative round-trip efficiency for residential battery storage, with a representative 5 kW, 12.5 kWh system. Manufacturers publish their own figures. The Enphase IQ Battery 5P data sheet lists 90% AC round-trip efficiency, measured from AC into the battery to AC out at 50% of its power rating, and 96% DC round-trip efficiency. The AC figure is the one that matters for a bill, because your meter counts AC kWh. Use your own battery’s AC figure if its data sheet gives one, and 85% if it does not.

What a grid-charged kWh is worth on real rates

On a flat rate, a grid-charged kWh always loses about 15% of its price to losses. On a time-of-use rate, it earns the gap between the peak price and the marked-up off-peak price. The chart runs the formula, with no wear allowance, on four rates.

Value of one grid-charged kWh delivered at the peak, at 85 percent round-trip efficiencyOn the fictional example rate, a kWh charged off-peak at 8 cents and delivered at the 31 cent peak is worth 21.6 cents. On KU's RTOD-Energy rate it is worth 14.9 cents, on LG&E's RTOD-Energy rate 8.4 cents, and on LG&E's flat Rate RS it loses 2.0 cents.−205101520Cents gained per kWh delivered (negative is a loss)Example rate (fictional)21.6KU RTOD-Energy14.9LG&E RTOD-Energy8.4LG&E Rate RS (flat)−2.0
Value per kWh delivered = peak price − off-peak price ÷ 0.85, no wear allowance. Example rate (fictional): 31 cents peak, 8 cents off-peak. KU RTOD-Energy: $0.24040 on-peak, $0.07811 off-peak (KU tariff Sheet No. 6). LG&E RTOD-Energy: $0.19307 on-peak, $0.09312 off-peak; Rate RS: $0.11499 at all hours (LG&E tariff Sheets No. 5 and 6). Kentucky prices effective September 1, 2026, base charges before riders and taxes, checked November 22, 2026.

Flat rates: always a loss

On a flat rate the peak price and the charging price are the same number, so the formula reduces to a loss of P × (1 ÷ η − 1). On LG&E’s Rate RS energy charge of $0.11499 per kWh (Sheet No. 5, effective September 1, 2026), charging from the grid costs $0.11499 ÷ 0.85 = $0.1353 per kWh delivered to avoid $0.11499. You lose about 2.0 cents on every kWh. A battery on a flat rate earns its keep from storing solar and from backup, not from the grid.

LG&E and KU time-of-day rates

LG&E’s optional RTOD-Energy rate charges $0.19307 per kWh on-peak and $0.09312 off-peak (Sheet No. 6, effective September 1, 2026). Grid charging costs $0.09312 ÷ 0.85 = $0.1096 per kWh delivered, so each kWh moved earns $0.19307 − $0.1096 = $0.0835, about 8.4 cents. At the Enphase data sheet’s 90%, it earns $0.19307 − ($0.09312 ÷ 0.90) = $0.0896, about 9.0 cents.

KU’s version of the same rate has a wider gap: $0.24040 on-peak and $0.07811 off-peak (KU tariff Sheet No. 6, issued August 28, 2026, effective September 1, 2026). The charging cost is $0.07811 ÷ 0.85 = $0.0919, and each kWh earns $0.24040 − $0.0919 = $0.1485, about 14.9 cents.

Two conditions on both utilities’ rates limit who can use these numbers. RTOD-Energy needs an AMI meter, and enrollment on RTOD-Energy and RTOD-Demand together is capped at 500 customers, accepted first come, first served. A customer who leaves for Rate RS may not be allowed back for 12 months. Both utilities set these windows in Eastern Standard Time, so on a daylight-time clock the summer peak reads one hour later. The general mechanics of rating periods and price ratios are in how time-of-use rates work.

Example (fictional). The site’s example rate charges 31 cents from 4 to 9 p.m. on weekdays and 8 cents from 9 p.m. to 7 a.m. Charging from the grid costs $0.08 ÷ 0.85 = $0.0941 per kWh delivered, so each kWh earns $0.31 − $0.0941 = $0.2159. The fictional example battery holds 13.5 kWh usable with a 20% reserve, leaving 10.8 kWh to spend. Filled entirely from the grid and fully used at the peak, it needs 10.8 ÷ 0.85 = 12.7 kWh at 8 cents ($1.02) and avoids 10.8 kWh at 31 cents ($3.35), a gain of $2.33 for that day. This example rate is not a utility tariff; it is built to show a wide spread.

Solar first, grid second: when grid charging adds nothing

If you have solar, grid charging competes with your own panels, and the panels usually win. The cost of storing a solar kWh is the export credit you give up, which on many tariffs is below the off-peak price. Grid charging is then a top-up for the shortfall on days when the forecast says solar surplus will not fill the battery before the peak.

Compare the export credit with the off-peak price

Under LG&E’s NMS-2 net metering rider (Sheet No. 58, effective February 16, 2026), exported energy earns a dollar-denominated bill credit of $0.07089 per kWh, applied to energy charges and per-kWh riders. A solar kWh stored instead of exported therefore costs 7.089 cents. A grid kWh bought off-peak on RTOD-Energy costs 9.312 cents. Storing solar is cheaper by 2.22 cents per kWh put in, so the battery should take every kWh of surplus it can before the grid supplies the rest.

Homes on LG&E’s older NMS-1 rider are in a different position. NMS-1 credits are kWh, not dollars, and on a time-of-day rate they offset use only within the same time-of-day block (Sheet No. 57). Before deciding anything on NMS-1, work out what an exported kWh is worth in the block where it lands. The solar export after NEM 3.0 article covers the general case of homes whose exports earn less than retail.

Why the example home’s clear day needs no grid at all

On the fictional example home’s clear April weekday, the scheduled battery fills from solar surplus by about 11 a.m., holds through the afternoon, covers the house from 5 to 9 p.m. and still ends the peak with 5.7 kWh, 3.0 kWh above its 2.7 kWh reserve. Any grid energy bought that night would have displaced solar that was free to store, and the battery would have ended the day fuller. On days like that, the right amount of grid charging is zero. The example home walkthrough shows every hour of that fictional day.

Top up only the shortfall

The useful question is not “grid charging on or off” but “how many kWh from the grid tonight”. The answer depends on tomorrow’s solar forecast and the house’s expected use in the peak.

Example (fictional). Suppose a cloudy weekday on which the forecast shows only 3.0 kWh of solar surplus, and the example home uses 9.9 kWh between 4 and 9 p.m., the same as on its April profile (1.4 + 2.0 + 2.4 + 2.2 + 1.9 kWh). The battery starts the night at its 2.7 kWh reserve.

  • Solar only. The 3.0 kWh of surplus delivers 3.0 × 0.85 = 2.55 kWh at the peak. The house buys the other 9.9 − 2.55 = 7.35 kWh at 31 cents: $2.28.
  • With a grid top-up. To deliver those 7.35 kWh from the battery, it needs 7.35 ÷ 0.85 = 8.65 kWh from the grid at 8 cents: $0.69. The peak purchase of $2.28 disappears.
  • Gain from the top-up: $2.28 − $0.69 = $1.59 for that day.

The top-up takes about 1.7 hours at the battery’s 5 kW (8.65 ÷ 5), so it fits between 3 and 5 a.m., after the car finishes charging at 3 a.m. Total delivery is 2.55 + 7.35 = 9.9 kWh, inside the 10.8 kWh above the reserve.

The cost of a wrong forecast is small

Forecasts miss. If the battery is topped up from the grid and the sun then produces more surplus than expected, the extra solar goes out as exports instead of into the battery. You paid the off-peak price for energy you could have stored for the export credit. The loss is the difference between the two, per kWh of overlap: 1 cent on the fictional example rate (8 − 7), and 2.22 cents on LG&E RTOD-Energy with NMS-2 (9.312 − 7.089). Compare that with what an empty battery costs at the peak, 8.4 to 21.6 cents per kWh in the chart above, and erring on the side of a top-up is usually the cheaper mistake. Under-filling is the expensive one.

Winter and low-solar days: where grid charging matters most

Grid charging earns most on the days solar contributes least: short winter days, overcast weeks and any rate with a morning peak. Those are also the days when a solar-only battery sits partly empty through the expensive hours.

LG&E and KU’s winter double peak

LG&E’s RTOD-Energy rating periods are set in Eastern Standard Time all year (Sheet No. 6.1). From April through October, weekday on-peak hours are 1 to 5 p.m.; everything else, including weekends, is off-peak. From November through March, there are two weekday peaks: 6 to 10 a.m. and 6 to 10 p.m., with off-peak hours from 10 a.m. to 6 p.m. and from 10 p.m. to 6 a.m.

That winter shape changes the battery’s job. A morning peak that starts before sunrise cannot be covered by today’s solar, only by energy stored overnight. And the midday off-peak window between the two peaks is a second chance to recharge, from whatever solar there is plus the grid.

Season (LG&E RTOD-Energy) Weekday on-peak When the battery can recharge off-peak Role of grid charging
April to October 1 to 5 p.m. EST 5 p.m. to 1 p.m. (overnight and morning) Small on clear days: morning solar usually fills the battery before 1 p.m.
November to March 6 to 10 a.m. and 6 to 10 p.m. EST 10 p.m. to 6 a.m. and 10 a.m. to 6 p.m. Large: overnight charging covers the morning peak; midday charging tops up for the evening
Weekends, all year None All hours None for price; any charging is for backup

Summer on-peak hours line up with strong afternoon sun, so a solar home often covers part of the peak directly. In winter the evening peak starts after dark and the morning peak before the panels produce much.

Example (fictional). Suppose a household on LG&E’s RTOD-Energy rate uses 4.0 kWh in the 6 to 10 a.m. peak and 7.0 kWh in the 6 to 10 p.m. peak on a January weekday, and owns a battery like the fictional example one: 10.8 kWh usable above its reserve, 85% round-trip efficiency. Solar is ignored to keep the arithmetic clean.

  • Morning cycle. The battery charges overnight, 10 p.m. to 6 a.m., enough to deliver 4.0 kWh: 4.0 ÷ 0.85 = 4.71 kWh at $0.09312 = $0.44. It avoids 4.0 kWh at $0.19307 = $0.77. Gain: $0.33.
  • Evening cycle. It recharges between 10 a.m. and 6 p.m. to deliver 7.0 kWh: 7.0 ÷ 0.85 = 8.24 kWh at $0.09312 = $0.77. It avoids 7.0 kWh at $0.19307 = $1.35. Gain: $0.58.
  • Day total: $0.33 + $0.58 = $0.92, which matches 11.0 kWh × $0.0835.

Any midday solar that charges the battery instead of the grid improves the evening cycle, because solar costs 7.089 cents under NMS-2 instead of 9.312. The hypothetical household’s loads are invented for the arithmetic; the prices are LG&E’s base energy charges effective September 1, 2026, before riders and taxes.

The example moves 11.0 kWh through a battery with 10.8 kWh above its reserve in one day. Two cycles a day earn more, and they also use warranty throughput twice as fast, which is the next question.

The wear allowance: cycles, throughput and warranty terms

Every kWh a battery moves uses a little of its warranted life. That cost is real only if the warranty’s cycle or throughput limit, not its calendar limit, is the one you will reach first. When it is, a wear allowance belongs in the break-even test.

Read the warranty’s limits as a race

Battery warranties usually end at whichever comes first: a number of years, a number of cycles, or an amount of energy throughput. Two published examples:

  • The Enphase IQ Battery 5P data sheet lists a limited warranty of “up to 15-year or 6,000 cycles”, whichever occurs first, with more than 60% capacity.
  • FranklinWH’s aPower product page lists 13.6 kWh, a 12-year warranty, 43 MWh of throughput and more than 70% state of health at the end of the warranty.

Now run each one as a race between calendar and use.

One cycle a day. Fifteen years of one full cycle a day is 15 × 365 = 5,475 cycles, below Enphase’s 6,000. The calendar limit arrives first, so a single daily cycle uses no warranty that the calendar was not going to end anyway.

Extra winter cycles. November through March has 151 days, about 108 of them weekdays (151 × 5 ÷ 7). Add one extra cycle on each of those weekdays and the battery runs 365 + 108 = 473 cycles a year. It reaches 6,000 cycles in 6,000 ÷ 473 = 12.7 years, before the 15-year mark. How the warranty counts a cycle, whole or partial, is defined in the warranty document, so read that before relying on the count.

Throughput. For the FranklinWH terms, 43,000 kWh ÷ 13.6 kWh = 3,162 full-capacity equivalents. A battery that moves its full 13.6 kWh every day reaches that in 3,162 days, about 8.7 years, well before 12. One that moves 80% of its capacity a day (10.9 kWh) takes 43,000 ÷ (10.88 × 365) = 10.8 years. Whether throughput is counted on the way in or on the way out is, again, in the warranty text.

When to add a wear allowance

If the calendar limit comes first under your expected use, set w to zero: the extra cycles cost nothing the warranty covers. If a cycle or throughput limit comes first, each extra kWh shortens the covered period. A simple allowance is what you would pay for the warranted capacity divided by the warranted kWh, applied only to the cycles that push you past the calendar pace. Our article on battery warranties and daily cycling works through warranty documents in detail.

The table shows what an allowance does to the break-even peak price. Allowances of 2 and 4 cents are assumptions chosen to show the effect, not estimates of any battery’s wear.

Off-peak price paid90% efficient, no wear85% efficient, no wear85%, plus 2 cents wear85%, plus 4 cents wear
6.0 cents6.67 cents7.06 cents9.06 cents11.06 cents
7.811 cents (KU RTOD-Energy)8.68 cents9.19 cents11.19 cents13.19 cents
8.0 cents (example rate, fictional)8.89 cents9.41 cents11.41 cents13.41 cents
9.312 cents (LG&E RTOD-Energy)10.35 cents10.96 cents12.96 cents14.96 cents
10.0 cents11.11 cents11.76 cents13.76 cents15.76 cents
12.0 cents13.33 cents14.12 cents16.12 cents18.12 cents
Break-even peak price = off-peak price ÷ efficiency + wear allowance. Grid charging pays when your peak price is above the figure in the cell. Kentucky off-peak prices from KU and LG&E tariff Sheet No. 6, effective September 1, 2026, base charges before riders and taxes. The wear allowances are illustrative assumptions.

Read across a row to see how much margin each rate has. LG&E’s on-peak price of 19.307 cents clears the 14.96-cent bar even with a 4-cent allowance. KU’s 24.040 cents clears it with room to spare. A rate with a 12-cent off-peak price would need a peak above 14 cents before any wear is counted.

Battery modes: three behaviors under many names

Every home battery app offers some version of three behaviors: store solar and use it whenever the house needs power, charge and discharge by the rate clock, or hold the battery full for outages. Grid charging lives in the second one, and usually behind a separate permission.

Behavior What the battery does Tesla app Enphase data sheet FranklinWH app
Store solar, use it when the house needs it Charges from surplus solar, discharges whenever the house draws more than the panels make Self-Powered Self-Consumption Self-Consumption
Follow the rate clock Charges when energy is cheap and discharges when it is expensive; may charge from the grid if allowed Time-Based Control TOU Time of Use
Hold for outages Stays full and waits for an outage Backup reserve set to 100% Backup Emergency Backup

Sources for the names: Tesla’s Time-Based Control and Self-Powered support pages, read as Wayback Machine captures because Tesla’s site refused automated requests; the Enphase IQ Battery 5P data sheet, which lists “Backup, Self-Consumption, and time-of-use (TOU) modes”; and FranklinWH’s Storm Hedge support page, which refers to Self-Consumption and Time of Use modes and an Emergency Backup mode.

What the rate-clock mode does with the grid

Tesla’s page describes Time-Based Control as charging “when energy costs from your utility are low” and powering the home “when energy costs are high”, and says that when the mode is enabled, Powerwall “will begin to charge from and discharge to the grid” to take advantage of price periods. The mode works from the utility rate plan entered in the app, so a wrong or outdated rate plan produces a wrong schedule.

Grid charging itself is a separate switch. Tesla’s Storm Watch page notes that “the availability of the Grid Charging setting in the Tesla app is set by your Certified Installer by default.” If you cannot find the setting, the installer decided at commissioning whether it appears, usually because of the interconnection terms described in the next section.

Self-use is not wrong, only incomplete

A self-use mode is the right choice on a flat rate, where the only gain is keeping solar at home. On a time-of-use rate it can empty the battery in cheaper hours before the peak arrives, and it never charges from the grid on a cloudy day. A rate-clock mode fixes the first problem only if someone keeps the rate plan current for every season and day type. The battery homes page explains how mode, reserve and rate interact for a solar-plus-storage household.

The reserve sits on top of every mode

Each mode works above a backup reserve, the share of the battery kept for outages. Tesla’s Backup Reserve page notes that a 100% reserve “prevents use of Self-Powered mode or Time-Based Control mode”. Grid charging can also refill that reserve before a storm, which is the other main reason owners turn it on. The reserve trades backup hours against daily savings, and the backup reserve page shows that trade for the fictional example battery.

Rules that can block grid charging or grid export

Whether a battery may charge from the grid, and whether it may send grid-charged energy back out, is set by the interconnection agreement, the utility’s tariff and any program you join, not by the app. Check all three before counting on grid charging.

Interconnection terms and non-exporting batteries

Some utilities connect batteries on the condition that they never export, or that they never charge from the grid, so that grid energy cannot be sold back as solar. Equipment makers build settings for both. Enphase’s Power Control page describes a “battery import only” setting for “meeting utility requirements for non-exporting batteries” and a “battery export only” setting that lets the battery export under NEM 3.0, California’s net billing tariff. Its IQ Battery 5P data sheet also lists “NEM integrity” among the battery’s services.

The two settings are mirror images. An import-only battery may charge from the grid but discharges only to the house. An export-only battery may send energy to the grid but charges only from solar. Which one your system uses decides whether grid charging is available at all.

Grid charging is a local fact, not a feature

Lawrence Berkeley National Laboratory’s 2024 study of battery reserves, Bill Savings vs. Backup Power, modeled several tariff variants because the rules differ: by default the batteries charged only from surplus solar and discharged only to meet the home’s net load, and separate cases allowed grid charging, grid discharging or both. Its conclusions note that “allowing grid charging largely obviates the need for customers to make” the trade-off between bill savings and backup, because a battery that can charge from the grid can be refilled before an outage.

LG&E’s net metering riders describe the generating facility (solar, wind, biomass, biogas or hydro, up to 45 kW) and how exports are credited; the rider sheets do not address batteries. For your home, the documents that decide are the signed interconnection agreement and the installer’s commissioning settings. Ask the installer which mode the battery was commissioned in and whether grid charging was enabled, and ask the utility if the agreement is unclear.

Utility battery programs

Programs that pay batteries for grid events come with their own rules. LG&E and KU run an interest list for a Bring Your Own Battery pilot, which the sign-up page says will be available only to customers with residential-style battery systems on RS and GS rates. A household that needs RTOD-Energy for grid charging to pay would therefore face a choice between the two. In any such program, the utility’s event instructions override your own schedule on event days, so read the program terms for event frequency, reserve treatment and eligible rates before enrolling.

Demand charges: a different reason to charge before the peak

On a residential demand rate, the battery’s value comes from holding down the highest 15-minute load in the billing month, not from shifting kWh. Grid charging then matters because the battery must have energy in it every time a peak-window spike could happen, and because charging too fast can create a demand charge of its own.

How LG&E’s RTOD-Demand bills

LG&E’s RTOD-Demand rate (Sheets No. 7 and 7.1, effective September 1, 2026) charges a single energy price of $0.06427 per kWh at all hours, a base demand charge of $4.32 per kW and a peak demand charge of $9.46 per kW. Demand is “the average kW demand delivered to the Customer during the 15-minute period of maximum use during the month”. Base hours are all hours; peak hours follow the same windows as RTOD-Energy: 1 to 5 p.m. on summer weekdays, and 6 to 10 a.m. and 6 to 10 p.m. on winter weekdays, in Eastern Standard Time.

Two things follow for a battery:

  1. Energy shifting loses money on this rate. Energy costs $0.06427 at every hour, so a grid-charged kWh costs $0.06427 ÷ 0.85 = $0.0756 delivered to avoid $0.06427. The value is entirely in the demand charges.
  2. Charging speed matters. A battery that charges at its full rating while the dryer and water heater run can set the month’s base demand in the middle of the night. Each kW added to the month’s highest 15 minutes costs $4.32.

Example (fictional). Suppose a household on RTOD-Demand runs an oven, a dryer and the heat pump together for 15 minutes in a winter evening peak, drawing 9 kW. A 5 kW battery that covers 5 kW of that draw brings the month’s peak demand down to 4 kW, saving 5 kW × $9.46 = $47.30 on that month’s peak demand charge, but only if the battery has charge for every such spike in every peak window that month. If the battery then charges overnight at 5 kW while the house draws 3 kW, it sets an 8 kW base demand. Charging at 2 kW over a longer stretch would keep the overnight total at 5 kW, and the 3 kW difference is worth 3 × $4.32 = $12.96 on that month’s base demand charge. The household’s loads are invented for the arithmetic; the charges are LG&E’s base charges before riders and taxes.

A demand rate rewards a schedule that plans for the whole month, not one day: a single missed spike sets the charge for every day of the billing period.

Tax credits no longer shape the decision

The federal Residential Clean Energy Credit (section 25D) no longer applies to new batteries, so it is not a reason to configure charging one way or another on a system installed in 2026. The IRS page on the Residential Clean Energy Credit lists “battery storage technology (beginning in 2023)” with a capacity of at least 3 kilowatt hours among qualified property, and states that “the credit is not available for any property placed in service after December 31, 2025.”

For a battery placed in service after that date, the grid-charging decision is purely about the rate, the hardware, the warranty and the interconnection terms. If you claimed the credit for an earlier system and want to know whether anything about how it is operated matters for that claim, that is a question for a tax professional. Culni gives no tax advice.

How a daily schedule makes the call

Run as a habit, the test becomes a nightly decision: how many kWh to buy tonight, if any, given tomorrow’s rate windows, solar forecast and expected use. A fixed setting cannot make that call; it either always charges from the grid or never does.

A schedule built for this works through the same steps every evening:

  1. Read tomorrow’s day type. Weekday or weekend, summer or winter, one peak or two, and any holiday the tariff treats as a weekday or weekend.
  2. Estimate peak-window use not covered by solar. That is the energy the battery should deliver.
  3. Estimate solar surplus before the peak. At the export credit, it is the cheapest charging energy available.
  4. Buy the shortfall off-peak, only if the test passes. Peak price minus off-peak price ÷ efficiency minus wear must be positive.
  5. Respect the reserve and the rules. Never plan below the backup reserve, and never grid charge where the equipment or the interconnection agreement does not allow it.

Culni is home energy software that reads a home’s electricity rate and runs one daily schedule across rooftop solar, a home battery, EV charging and flexible loads, then checks the result against the bill each month. Its battery scheduling page shows how each hour gets a charge, hold or discharge instruction with a reason, including when grid charging is and is not used. Whether a particular battery can take those instructions is confirmed home by home.

Before you turn grid charging on: a checklist

Work through these in order. Most households can answer them from three documents: the rate schedule, the battery’s data sheet and warranty, and the interconnection paperwork.

  1. Find your peak and off-peak prices on the tariff sheet, with their effective date, and note the hours for each season and day type.
  2. Find your battery’s AC round-trip efficiency on its data sheet. Use 85% if none is published.
  3. Compute the break-even peak price: off-peak price ÷ efficiency. If your peak price is not above it, stop: grid charging loses money on your rate.
  4. Compare the off-peak price with your export credit. If the export credit is lower, solar surplus should fill the battery first and the grid should only top up.
  5. Read the warranty’s limits as a race. If cycles or throughput will run out before the years, add a wear allowance and recompute.
  6. Confirm grid charging is permitted by the interconnection agreement and enabled at commissioning. Ask the installer which operating mode was set.
  7. Check any utility program’s eligibility rules against the rate you would need. Some programs require a specific rate schedule.
  8. On a demand rate, cap the charging power so overnight charging does not set the month’s base demand.
  9. Revisit the answer each season and after every rate change. A winter double peak and a summer afternoon peak call for different schedules.

The battery arbitrage calculator runs the daily value with your own capacity, reserve, efficiency and prices; enter your off-peak price as the cost of charging energy to test grid charging, or your export credit to test solar. The home battery checklist lists the questions to settle with an installer before the battery is commissioned. To have the test run on your own tariff, battery and solar, with every assumption written down, you can send your rate and device list.