Time-of-use rates price each kWh by hour, weekday and season. See how peak windows, price ratios and fixed charges decide if you pay less than a flat rate.

Reader question
How does a time-of-use rate decide what each kWh costs, and will my household pay less on one than on a flat rate?
A stone sundial without numerals stands in a small walled garden, its long shadow falling across a path of alternating ember and indigo paving stones.

A time-of-use rate charges a different price for each kWh depending on when your meter records it: the hour, whether it falls on a weekday, and the season. It costs you less than a flat rate only when a small enough share of your kWh lands in the expensive peak window. On LG&E’s residential time-of-day rate in Kentucky, that break-even share is about 22% of your monthly use, measured on the base energy charges in the tariff checked in November 2026. Households that can move EV charging, water heating, battery charging or part of their heating and cooling out of the peak usually clear that bar; households whose use is pinned to the peak usually do not.

The rest of this article takes a time-of-use (TOU) rate apart into the three levers every schedule has, compares how four utilities set them, and shows the arithmetic for deciding whether one would cost your household less. All prices are base charges as published, before riders and taxes, unless a section says otherwise.

How a time-of-use rate prices each kWh

A TOU rate divides the week into rating periods and gives each period its own price per kWh. Your bill multiplies the kWh recorded in each period by that period’s price, then adds charges that do not depend on the clock. Three levers decide what you pay:

  1. The rating periods. Which hours are on-peak, which are off-peak, and sometimes a middle period called mid-peak, partial-peak, shoulder or super off-peak. Periods change by weekday or weekend, by holiday and by season, and the tariff states which clock they follow.
  2. The price ratio. How far the on-peak price sits above the off-peak price. The gap, in cents per kWh, is what each kWh you move out of the peak is worth.
  3. The charges that do not move. Daily or monthly customer charges, adjustment clauses (riders) and taxes. They are on the bill whichever rate you choose, and they shrink any saving when you express it as a share of the whole bill.

Some utilities add a fourth lever by stacking tiers on top of the periods. PG&E’s E-TOU-C plan, for example, charges a peak price from 4 to 9 p.m. every day and also bills energy within a seasonal Baseline Allowance at a lower price than energy above it. On a plan like that, the price of a kWh depends on both its hour and how much you have already used that month.

Billing by period needs a meter that records when you use power. EIA reports that about 73% of US residential meters were advanced (AMI) meters in 2022, and it defines AMI as meters that measure and record usage at least hourly and send the data to the utility and the customer at least once a day. LG&E and KU make an AMI meter a condition of their time-of-day rate.

Where the numbers come from

No national table lists TOU prices. EIA states plainly that it does not collect or publish rates, tariffs or peak and off-peak prices; it publishes only counts of customers enrolled in time-based rates. What EIA does publish is the average residential price per kWh by state. In August 2026, the preliminary figures in Electric Power Monthly Table 5.6.A were 18.16 cents for the US, 13.80 cents for Kentucky, 17.17 cents for Colorado and 29.75 cents for California. Those averages tell you how expensive power is in your state. They say nothing about how your utility splits the day, which is why the tariff sheet is the document to read. Our guide to reading an electric rate schedule walks through one section by section.

Rating periods: hours, weekdays, holidays and seasons

The peak window is the block of hours your utility prices highest, and it differs more from one utility to the next than most national explainers suggest. Some peaks last three hours, some eight; some apply every day, others only on weekdays; and at least one utility in this comparison has two peaks a day in winter.

The Colorado Public Utilities Commission gives the reason peaks exist: on-peak periods “are set when demand is highest and costs are greater to generate and deliver energy,” and utilities “must design their system to meet peak demand even though less than 10% of electricity use occurs during the peak” (Colorado PUC). Each utility draws its windows around its own system’s most expensive hours, so the windows below look different.

Weekday on-peak windows on six published time-of-use schedulesEach row is one weekday from midnight to midnight. LG&E and KU put the summer peak at 1 to 5 p.m. Eastern Standard Time, which is 2 to 6 p.m. on a daylight-time clock, and use two winter peaks, 6 to 10 a.m. and 6 to 10 p.m. Xcel Colorado's peak is 5 to 9 p.m., PG&E E-TOU-C 4 to 9 p.m., PG&E E-TOU-D 5 to 8 p.m. and SCE TOU-D-PRIME 4 to 9 p.m. All other hours are lower priced.Lower-priced hoursOn-peakLG&E and KU summer, tariff (EST)LG&E and KU summer, clock (EDT)LG&E and KU winter (EST)Xcel Colorado, all yearPG&E E-TOU-C, every dayPG&E E-TOU-D, weekdaysSCE TOU-D-PRIME, summer12 a.m.6 a.m.Noon6 p.m.12 a.m.
Weekday on-peak windows as published. Sources: LG&E tariff Sheet No. 6.1 and the LG&E and KU time-of-day page; Colorado PUC TOU page; PG&E and SCE TOU plan pages; all checked November 22, 2026. Weekends, holidays and SCE's winter mid-peak are described in the table below.
Utility and plan Weekday on-peak Weekends and holidays Seasons Share of a week’s hours on-peak
LG&E and KU, RTOD-Energy April to October: 1 to 5 p.m. EST. November to March: 6 to 10 a.m. and 6 to 10 p.m. EST Weekends all off-peak; a legal holiday on a weekday counts as a weekday Two, with the same prices in both 11.9% in summer, 23.8% in winter
Xcel Energy Colorado (default TOU) 5 to 9 p.m. on non-holiday weekdays, all year Weekends and holidays off-peak Summer (June to September) prices higher 11.5% of the year’s hours (1,008 of 8,760)
PG&E E-TOU-C 4 to 9 p.m. every day Same as weekdays Summer June 1 to September 30; winter October 1 to May 31 20.8%
PG&E E-TOU-D 5 to 8 p.m. weekdays Weekends and most holidays off-peak Summer and winter 8.9%
SCE TOU-D-PRIME Summer: 4 to 9 p.m. weekdays Summer weekends: 4 to 9 p.m. is mid-peak Summer June to September; winter October to May, with 4 to 9 p.m. mid-peak and 8 a.m. to 4 p.m. super off-peak every day 14.9% in summer

The last column is simple arithmetic: peak hours per week divided by the 168 hours in a week (for Colorado, the Commission’s own count of on-peak hours in 2026). It matters later, because it is the share of your use that would fall on-peak if your home drew the same power every hour.

Weekends and holidays

Weekends are the easy part: every schedule above prices them off-peak or mid-peak. Holidays are where tariffs differ. PG&E’s E-TOU-D and Xcel’s Colorado rate treat most holidays as off-peak. LG&E and KU’s tariff does the opposite: “If a legal holiday falls on a weekday, it will be considered a weekday,” so the Monday of a holiday weekend still has a peak. A household that runs the dryer, the oven and the car charger on a holiday afternoon pays peak prices for them on that rate.

Standard time and daylight time

The tariff also chooses a clock. LG&E and KU’s Sheet No. 6.1 sets the rating periods “in Eastern Standard Time year-round.” Clocks move in March and November; the tariff does not. The summer peak written as 1 to 5 p.m. EST arrives at 2 to 6 p.m. on a daylight-time kitchen clock, and the utilities’ time-of-day page prints both. The winter peaks sit at 6 to 10 a.m. and 6 to 10 p.m. by the clock from the first Sunday in November through the second Saturday in March. In the stretches of March and early November when daylight time is in force, they read 7 to 11 a.m. and 7 to 11 p.m. Customers in the Central Time zone see every window one hour earlier.

A timer set by the kitchen clock in July, built for a 1 to 5 p.m. peak, would start the dishwasher at 5 p.m. EDT, which is 4 p.m. EST and still inside the peak. Any schedule you build has to store the window in the tariff’s own time and convert it date by date.

Winter peaks that come twice a day

National articles usually describe one late-afternoon peak, the pattern in California and Colorado. LG&E and KU’s winter schedule has two four-hour peaks every weekday from November through March, one across breakfast and one across the evening. The tariff does not give its reasons, but the pattern fits the Colorado PUC’s description of peaks as the hours of highest demand: on winter mornings and evenings, heating, hot water and household routines pile up at the same time.

Two winter peaks double the hours you must manage. In summer, 20 of the week’s 168 hours are on-peak; in winter, 40 are. A home whose biggest winter loads are a heat pump recovering from a night setback and a water heater reheating after morning showers will find both of them inside the 6 to 10 a.m. EST window.

The price ratio: how far apart peak and off-peak prices are

The ratio between the on-peak and off-peak price sets how much you gain for each kWh you move and how much you lose for each kWh you cannot. The difference in cents is the more useful number for a household: it is the value of one kWh shifted out of the peak.

Utility and plan (period) On-peak per kWh Off-peak per kWh Ratio Value of each kWh moved
LG&E RTOD-Energy (all year) $0.19307 $0.09312 2.07 to 1 9.995 cents
KU RTOD-Energy (all year) $0.24040 $0.07811 3.08 to 1 16.229 cents
Xcel Colorado (summer) $0.21277 $0.07884 2.70 to 1 13.393 cents
Xcel Colorado (October to May) $0.18331 $0.06792 2.70 to 1 11.539 cents
SCE TOU-D-4-9PM (summer weekday) 59 cents 33 cents 1.79 to 1 26 cents
SCE TOU-D-PRIME (summer weekday) 61 cents 26 cents 2.35 to 1 35 cents

Sources and basis: LG&E tariff Sheet No. 6 and KU tariff Sheet No. 6, effective September 1, 2026, base charges before riders and taxes; Colorado PUC table of new TOU base rates; SCE’s plan page, rounded to the cent and shown for customers who take both delivery and generation from SCE. All checked November 22, 2026.

Three things stand out. First, the ratio and the value per kWh do not move together: SCE’s TOU-D-4-9PM has the smallest ratio in the table, yet each kWh moved is worth 26 cents, more than on any Kentucky or Colorado rate, because all its prices are high. Second, the two Kentucky utilities share the same windows but not the same prices, so a kWh moved is worth 62% more on KU’s rate than on LG&E’s (16.229 divided by 9.995 is 1.62). Third, the Colorado PUC set Xcel’s ratio deliberately: “Rates during On-Peak hours will be 2.7 times higher than Off-Peak.”

The ratio also sets the penalty for doing nothing. The Colorado PUC calls Xcel’s design “revenue neutral,” meaning that for most customers a short peak at a higher price is offset by lower prices the rest of the day. A household that cannot move anything gets no help from that offset. As the Commission puts it, “charging an electric car mainly during the On-Peak period may cause an increase in bills.”

Charges that do not change with the clock

Every TOU bill carries charges that are the same whichever hour you use power, and they decide how large any saving looks next to the whole bill. On LG&E, both the standard residential Rate RS and RTOD-Energy charge a Basic Service Charge of $0.48 per day, which is $14.40 for a 30-day bill, and the tariff makes it the minimum charge. KU charges $0.58 per day on both rates, or $17.40 for 30 days. SCE’s TOU plans carry a Base Services Charge of $0.79 per day, $23.70 for 30 days, and SCE notes that its minimum charge no longer applies: a home with zero usage still pays the daily charge.

Then come the adjustment clauses. LG&E’s RTOD-Energy sheets list the same nine as Rate RS. They work in four different ways:

How the rider is charged LG&E examples Effect on the TOU decision
A price per kWh, the same at every hour Fuel Adjustment Clause and Off-System Sales factor (billed together, changing monthly); Demand-Side Management factor of $0.00206 per kWh on Rates RS and RTOD (Sheet No. 86.10, effective April 1, 2026) Adds the same amount to both rates, so it does not change which one wins
A percentage factor on the monthly bill amount Environmental Cost Recovery, Retired Asset Recovery, Pilot Generation Recovery Scales both bills by roughly the same percentage, so it changes the size of the gap a little but not its direction
Local charges on the bill Franchise fee, applied to the base rate and riders where a local government imposes one; school tax, a utility gross receipts license tax in counties that levy it Follow the bill amount, so they treat both rates alike
A flat amount Home Energy Assistance charge of $0.30 per month for residential customers (Sheet No. 93) Same on both rates

Two practical points follow. A savings figure should be worked out on energy charges, then judged against the whole bill, since the fixed charge will not shrink. And the terms around a rate matter as much as its prices. LG&E’s RTOD-Energy sheet says customers on it “will not be eligible for Company’s Budget Payment Plan.” If you rely on budget billing, that may decide the question before any arithmetic does.

The break-even test: how much of your use can fall on-peak

The break-even share is the fraction of your monthly kWh that can land on-peak before a two-period TOU rate costs more than the flat rate it replaces. Below it, the TOU rate is cheaper on energy charges; above it, the flat rate is. For a two-period rate, it takes one line:

Break-even on-peak share = (flat price minus off-peak price) divided by (on-peak price minus off-peak price).

For LG&E, comparing RTOD-Energy with Rate RS: ($0.11499 minus $0.09312) divided by ($0.19307 minus $0.09312) equals $0.02187 divided by $0.09995, or 0.2188. If less than about 21.9% of your kWh fall in on-peak hours, RTOD-Energy costs less in energy charges than Rate RS. For KU, using its Rate RS and RTOD-Energy sheets: ($0.11396 minus $0.07811) divided by ($0.24040 minus $0.07811) equals $0.03585 divided by $0.16229, or about 22.1%. The two utilities price differently but land within a quarter of a percentage point of each other.

There is a second way to see the same number. On LG&E, each kWh left on-peak costs 7.808 cents more than it would on Rate RS ($0.19307 minus $0.11499). Each off-peak kWh costs 2.187 cents less ($0.11499 minus $0.09312). One on-peak kWh therefore cancels the saving on about 3.57 off-peak kWh (7.808 divided by 2.187). One kWh in, 3.57 out: that is the same 21.9% (1 divided by 4.57).

Monthly energy cost of 1,000 kWh on LG&E Rate RS and RTOD-Energy by on-peak shareRate RS costs $114.99 for 1,000 kWh at any on-peak share. RTOD-Energy costs $93.12 if no kWh fall on-peak and rises by $9.995 for every 10 percent of use on-peak, reaching $133.10 at 40 percent. The two lines cross at an on-peak share of about 21.9 percent.$80$100$120$1400%10%20%30%40%Share of the month's kWh used in on-peak hoursBreak-even: 21.9% on-peakRate RS: $114.99 at any shareRTOD-Energy: $93.12 at 0%$133.10 at 40%
Energy charges for a hypothetical 1,000 kWh month on LG&E Rate RS ($0.11499 per kWh) and RTOD-Energy ($0.19307 on-peak, $0.09312 off-peak), base charges before riders and taxes; the $0.48 daily charge is the same on both and is left out. Source: LG&E tariff Sheets No. 5 and 6, effective September 1, 2026, checked November 22, 2026.

Compare the break-even with the hours

Now set the break-even next to the share of hours that are on-peak. In summer, LG&E’s peak covers 11.9% of the week’s hours; in winter, 23.8%. A home that drew exactly the same power every hour would put 11.9% of its summer kWh on-peak and pass the test easily, but would put 23.8% of its winter kWh on-peak and fail it, since 23.8% is above 21.9%. Real homes do not draw evenly: use tends to rise when people are awake and at home, and utilities draw their peaks around those same hours on the wider system. So a household that changes nothing should expect its winter on-peak share to be at or above the break-even, and its summer share to depend on how much air conditioning runs between 2 and 6 p.m. by the clock.

That is the most useful single fact about this rate: in Kentucky, summer is where RTOD-Energy is easy to win and winter is where it is easy to lose.

Rates with three periods

Many TOU plans have a middle price. The break-even then depends on two shares, not one, because a kWh moved from peak to the middle period saves less than one moved to off-peak. The site’s rate plan comparison calculator handles this. Its default example uses a fictional example rate (31 cents peak, 14 cents day, 8 cents off-peak, against a 13 cent flat rate) for a 900 kWh month with 45% of use off-peak. It finds a break-even of 10% of use in peak hours: at the default 25%, the TOU plan costs $139.95 against $117.00 flat. Those are example prices, not a tariff, but they show how a steep three-period rate tightens the test.

Which loads can move and which cannot

A load is shiftable when the energy can be used at a different hour without anyone noticing the difference: a car battery, a tank of hot water, a home battery, or the thermal mass of the house itself. The table sorts common household loads by how easily they leave a peak window.

Load Can it leave the peak? How Watch for
EV charging at home Yes, almost entirely Charger or vehicle schedule set to start after the peak Winter evening peak ends at 10 p.m. EST on LG&E and KU; a car plugged in at 6 p.m. must wait
Electric or heat pump water heater Mostly Heat the tank before the window; the stored water carries through Morning showers fall inside LG&E’s 6 to 10 a.m. EST winter peak
Home battery Yes, within its settings Charge from solar or off-peak power, discharge during the peak Two winter windows split one charge; the backup reserve limits what is available
Heating and cooling Partly Pre-cool or pre-heat before the window, then let the temperature drift Electric resistance backup heat on cold mornings can erase the gain
Dishwasher, laundry, pool pump Yes Delay-start timers Dryer heat and noise late at night
Cooking, lighting, refrigeration, electronics Little Not practical to move These set a floor under your on-peak share
Medical equipment No Should never be moved for price Ask the utility about medical rate options

The DOE’s Alternative Fuels Data Center notes that most EV drivers charge overnight at home, and that some utilities offer residential TOU rates or other rate incentives for charging. An EV is often the largest single load a household can move. At the fictional example home’s 35 miles a day, 3.5 miles per kWh and 10% charging loss, the car takes 11.1 kWh from the wall per day. Our article on the best rate for EV charging compares whole-home TOU, EV-only rates and flat rates for that decision.

Solar on a time-of-use rate

Rooftop solar changes when you buy power, not only how much. Under LG&E’s net metering rider NMS-2, for systems first in service on or after September 24, 2021, the company bills all energy you take from the grid at your standard rate and credits each exported kWh at $0.07089 (Sheet No. 58), whatever the hour. For a solar home on RTOD-Energy, solar output used in the house during the summer peak avoids $0.19307 per kWh, while output exported at noon earns $0.07089. In winter, LG&E’s peaks fall mostly at hours of weak or no sunlight, so solar does little for the on-peak share without a battery. Other utilities’ export rules differ, and some require a TOU rate for solar customers: SCE says customers on its Solar Billing Plan must take TOU-D-PRIME.

Moving a load versus storing energy

Shifting a load and storing energy are not worth the same per kWh. When a car charges at 11 p.m. instead of 6 p.m., the household saves the full price gap: 9.995 cents per kWh on LG&E’s rate. A battery loses some energy on the round trip. NREL’s Annual Technology Baseline adopts 85% as a representative round-trip efficiency for residential batteries (read from an archived copy dated May 2026, as the live site did not respond), so each kWh delivered in the peak needs about 1.18 kWh charged beforehand (1 divided by 0.85).

If that charge comes from the grid off-peak on LG&E’s rate, it costs $0.09312 divided by 0.85, or 10.955 cents, for each kWh later delivered, and that kWh avoids 19.307 cents: a gain of about 8.35 cents. With KU’s wider gap, the same arithmetic gives about 14.85 cents. Whether a battery may charge from the grid at all depends on its settings and the utility interconnection agreement, and battery scheduling explains how a schedule works within those limits.

A worked month on each rate

The examples below use LG&E’s published base prices on a fictional household to show how the break-even behaves in each season. They leave out riders and taxes, which apply to both rates.

Example (fictional). A Louisville household with a heat pump, an electric water heater and one EV uses 1,200 kWh in a 30-day January bill. With no changes, 30% of its kWh (360 kWh) fall in the two winter peaks and 840 kWh fall off-peak.

  • Rate RS: 1,200 kWh x $0.11499 = $137.99, plus 30 days x $0.48 = $14.40. Total $152.39.
  • RTOD-Energy, unchanged habits: 360 kWh x $0.19307 = $69.51, plus 840 kWh x $0.09312 = $78.22, plus $14.40. Total $162.13, which is $9.74 more than Rate RS.

Now the household moves the car’s weekday charging and the water heater’s evening reheats to after 10 p.m., taking 150 kWh out of the peaks. On-peak use falls to 210 kWh (17.5%) and off-peak use rises to 990 kWh.

  • RTOD-Energy, after shifting: 210 kWh x $0.19307 = $40.54, plus 990 kWh x $0.09312 = $92.19, plus $14.40. Total $147.13, which is $5.25 less than Rate RS.

The 150 kWh moved are worth 150 x $0.09995 = $14.99, the swing from $9.74 more to $5.25 less. The heat pump’s morning recovery is still inside the 6 to 10 a.m. window; that is what keeps on-peak use above 200 kWh.

Example (fictional). The same household in a 30-day July bill uses 1,000 kWh. Air conditioning pushes 15% (150 kWh) into the summer peak, 1 to 5 p.m. EST, which is 2 to 6 p.m. on the clock.

  • Rate RS: 1,000 kWh x $0.11499 = $114.99, plus $14.40. Total $129.39.
  • RTOD-Energy, unchanged habits: 150 kWh x $0.19307 = $28.96, plus 850 kWh x $0.09312 = $79.15, plus $14.40. Total $122.51, which is $6.88 less than Rate RS.
  • RTOD-Energy, with pre-cooling before 2 p.m. moving 60 kWh: 90 kWh x $0.19307 = $17.38, plus 910 kWh x $0.09312 = $84.74, plus $14.40. Total $116.52, which is $12.87 less than Rate RS.

These two fictional months show the break-even test in money. The summer month wins without effort because 15% is well below 21.9%. The winter month loses until the household moves its largest flexible loads. One winter month and one summer month are not a year: spring and fall months, a cold snap, a week of guests or a change in the rate itself would each move the result, and nobody should multiply either example by twelve.

Who tends to save, and who tends to pay more

Whether a TOU rate helps depends less on how much electricity a household uses than on how much of it can move and who will move it. The table sets out the usual cases; the break-even test above is how you check your own.

Household Likely result on a rate like RTOD-Energy Why
EV charged overnight on a timer Likely to save A large load moves entirely off-peak, every day
Battery set to cover the peaks Likely to save, if it covers both winter windows Peak kWh come from stored energy; round-trip losses cost a little
Water heater on a schedule Helps Stored hot water carries through the window
Solar without a battery Mixed Helps in the summer peak, little in winter peaks after dark
Heat pump with electric backup heat At risk in winter Morning recovery from a setback lands in the 6 to 10 a.m. EST peak
Someone home all afternoon with air conditioning At risk in summer, unless pre-cooling is practical The summer peak covers 2 to 6 p.m. on the clock
Small home with few large loads Little to gain Few kWh to move; the daily charge is the same either way
Medical equipment at home Ask the utility first Some utilities offer medical rate options; the Colorado PUC says a different flat rate may be available to Xcel customers with a verified medical condition

LG&E and KU state the risk themselves on their time-of-day page: “If you do not shift the time of day that you use energy or you consume energy during on-peak times, your bill may go up.” Their page lists the customers who could benefit as those who pay attention to which appliances run when, have a programmable thermostat, or use timers and delay starts.

Eligibility and switching rules

A rate you cannot get, or cannot leave, changes the decision. LG&E and KU’s RTOD-Energy needs an AMI meter and is capped at 500 customers on RTOD-Energy and RTOD-Demand combined, first come, first served. A customer who returns to Rate RS may not come back to the time-of-day rate for 12 months. SCE says a customer who switches to a TOU rate cannot switch again for a full 12 months, and its TOU-D-PRIME plan is for households that own or lease an EV or plug-in hybrid, a residential battery or an electric heat pump for water or space heating, which customers confirm when they enroll. In Colorado, the PUC says TOU is Xcel’s default and customers must contact Xcel to opt out to a seasonal flat rate. The Kentucky details, including how the 500-customer cap and the demand version of the rate work, are in our article on LG&E and KU’s time-of-day rates.

How to check a time-of-use plan before you switch

You can test a TOU plan against your own usage before you sign up, using a year of interval data and the tariff. The steps below are the same for any utility.

  1. Find every rate you are eligible for. Your bill names your current rate schedule. The utility’s rates page or your state commission’s tariff library has the others. The utility bill checklist lists what to look for on both.
  2. Read the rating periods exactly. Note the hours, the clock (standard or daylight), the months in each season, weekend and holiday treatment, and any middle period.
  3. Download 12 months of hourly or 15-minute usage. Many utilities with smart meters offer this in the online account, some as a Green Button file.
  4. Sort each interval into its rating period. Convert the timestamps to the tariff’s clock first. A spreadsheet can do this with a lookup table of hours by season and day type.
  5. Compute your on-peak share for each season. Compare it with the break-even share for your two rates: (flat price minus off-peak price) divided by (on-peak price minus off-peak price).
  6. List what you could move, in kWh per month. An EV’s daily kWh, a water heater’s reheats, a battery’s usable capacity above its reserve, and the cooling or heating you could shift by pre-conditioning. Then recompute the share.
  7. Price both rates in full. Use the energy charges, the daily or monthly charge, and a recent value for each rider. The time-of-use savings calculator gives a quick monthly figure; its default example moves 90 kWh at a 23-cent price difference for $20.70 a month, using the fictional example rate.
  8. Check the terms. Enrollment caps, meter requirements, the period before you may switch back, and whether budget billing remains available.

If the result is close, the deciding question is who will do the shifting every day. A delay-start button that someone forgets twice a week in January can be the difference between a winning month and a losing one.

How a daily schedule handles a time-of-use rate

A schedule for a home on a TOU rate has to know the rating periods by date and day type, in the tariff’s clock, and then decide hour by hour where each flexible kWh goes. Culni makes software that reads a home’s electricity rate and runs one daily schedule across rooftop solar, a home battery, EV charging and flexible loads such as water heaters and heat pumps, then checks the result against the bill each month.

Its rate engine stores each window in the tariff’s own time and converts it for every date, so a peak written in Eastern Standard Time lands on the right clock hour in July and in January. The home energy plan a homeowner receives starts with the rate decoded, including a comparison where the homeowner has a choice of rates, and shows every input behind each estimate. The fictional example home shows what that looks like for one clear spring weekday on an example rate, not a utility tariff. Whether a given home’s devices can be scheduled is confirmed home by home, and the device categories page explains how.

What to do next

Start with the arithmetic, not the sign-up form.

  • Get your tariff and your interval data, then compute your on-peak share for a summer month and a winter month.
  • Run the break-even for your flat rate and the TOU rate you are offered, or enter your numbers in the rate plan comparison calculator.
  • Write down what can move and who or what will move it: a charger schedule, a water heater timer, a battery mode, a thermostat program.
  • Check the terms that are not prices: enrollment caps, return rules, budget billing, medical options.
  • Recheck after a rate case. LG&E’s current RTOD-Energy prices took effect September 1, 2026; when a utility files new sheets, the break-even moves with them.

If you would like the comparison worked out for your own home, with your rate, your bills and your devices, you can send your rate plan and a recent bill and ask for a home energy plan.

TodayYour turn

Want this worked out for your home?

Send your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan and every assumption behind it.

Remote. No site visit needed.