Battery sizing worksheet
List your critical loads to find the energy per day, running power and battery capacity they need.
- You enter
- Each load with watts, hours per day and quantity
- You get
- Daily kWh, running kW and usable kWh for one day
- Allowances
- A 20% reserve kept and 95% inverter efficiency
- Download
- The list as a CSV to send with your request

Worksheet
The rows list the critical loads of the fictional example home. Edit them, add your own and download the result as CSV. Nothing leaves your browser.
| Load | Watts while running | Hours per day | Quantity | kWh per day | Remove |
|---|---|---|---|---|---|
| 1.50 | |||||
| 4.00 | |||||
| 0.80 | |||||
| 0.48 | |||||
| 0.36 | |||||
| 0.30 | |||||
| 0.36 |
Results
- Loads counted
- 7
- Running power if all run at once
- 2.83 kW
- Energy per day
- 7.80 kWh
- Usable capacity for one day of these loads (starting full, ending at the reserve)
- 10.3 kWh
Sizing a battery for backup starts with a list, not a brochure. Write down the loads you actually want running during an outage, how much power each one draws and for how many hours a day, and the worksheet adds them up into the two numbers that matter: energy per day in kWh, which sets the capacity you need, and running power in kW, which the battery must be able to deliver at once.
How to fill it in
Each row is one load, with four columns.
- Load. Name it the way you would label the circuit: “Refrigerator”, “Sump pump”, “Furnace blower”.
- Watts while running. The nameplate or the owner’s manual gives watts, or amps and volts (multiply them: a 4 amp motor on 120 volts is 480 watts). For plug-in loads, a plug-in energy meter gives a better number than the label, especially for a refrigerator, whose average draw is far below its compressor rating.
- Hours per day. Hours it runs during an outage, not on an ordinary day. A furnace blower runs longer in a cold snap, and a sump pump runs most during the storm that caused the outage.
- Quantity. Two identical freezers are one row with quantity 2.
Add a row for anything you would keep on, and remove anything you would switch off. When the list is right, download it as a CSV and attach it when you send your device list.
The formula in plain words
- Energy per load = watts × hours × quantity. The worksheet adds them up and divides by 1,000 for kWh per day.
- Running power = the sum of watts × quantity, as if every load ran at the same moment.
- Usable battery capacity for one day = kWh per day ÷ 0.95 (inverter efficiency) ÷ (1 minus the 20% reserve). That is the usable capacity that covers one day of these loads starting from a full battery and still ends the day at the reserve.
Example (fictional). The worksheet opens with seven loads: a refrigerator at an average 150 watts for 10 hours, a gas furnace blower at 500 watts for 8 hours, a sump pump at 800 watts for 1 hour, an internet modem and router at 20 watts for 24 hours, LED lights at 60 watts for 6 hours, phone and laptop charging at 100 watts for 3 hours, and a microwave at 1,200 watts for 0.3 hours. With 7 loads counted, the running power if all run at once is 2.83 kW, the energy per day is 7.80 kWh, and the usable battery capacity for one day of these loads is 10.3 kWh.
How to read the result
Energy per day against capacity. The fictional example home’s battery has 13.5 kWh usable, more than the 10.3 kWh this list needs for one day. For scale, NREL’s 2024 Annual Technology Baseline uses a 5 kW, 12.5 kWh system as its representative home battery. To turn your list into hours of backup at a given starting charge, divide the daily kWh by 24 for the average load and use the backup runtime calculator: 7.80 kWh a day is an average of 325 watts, which is where that calculator’s 330 watt example comes from.
Running power against the battery’s power rating. 2.83 kW is well inside a 5 kW battery’s continuous rating. If your total is close to or above your battery’s rating, some loads must take turns.
Start-up power. Motors (the sump pump, the furnace blower, a refrigerator compressor, a well pump) draw more for a moment when they start. The worksheet does not include that surge; ask your installer whether the battery can start your largest motor.
Limits
- No solar recharging is counted. Sunny days during an outage help; cloudy ones may not.
- Only backed-up circuits run. A load on your list does nothing if its circuit is not connected to the battery’s backup panel. Check with your installer which circuits are.
- Hours are estimates. Central air and electric resistance heat are large loads that can change the answer completely. Enter them honestly or plan to leave them off.
- The 20% reserve and 95% inverter efficiency are assumptions. Your own reserve and your inverter’s specification sheet may differ.
What to do next
Take the list into the outage readiness checklist, and if you are still choosing a battery, into the home battery checklist. The planning a system page covers the questions to settle before buying anything.
In a Culni plan, your critical loads list sets the backup reserve: the plan states the hours of backup the reserve gives for the loads you list, and the schedule never spends the battery below it. To have that worked out for your home, check my home and attach the CSV.
TodayYour turn
Send your rate and your devices
Your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan: your rate decoded, which devices can connect, the daily schedule and its estimated value with every assumption shown.
Remote. No site visit needed.