8 a.m. to noon
noon to 2 p.m.
2 to 5 p.m.
5 to 9 p.m.
in the example home
Solar homes without a battery
More from panels you already own, through the right rate, loads moved into sun hours and credits explained.
- 8 a.m. to noon exports surplus
- noon to 2 p.m. flexible loads run on solar
- 2 p.m. to 5 p.m. exports surplus
- 5 p.m. to 9 p.m. buys at the peak price
- You send
- Utility, rate plan, net metering terms and a recent bill
- You get
- A rate comparison and the loads worth moving
- Stays with you
- Inverter and export settings, with your installer
- Limits
- Without storage, only flexible loads can move

Rooftop solar produces the most in the middle of the day, when many households use the least. Without a battery, every kWh the house cannot use in that hour goes to the grid and earns your utility’s export credit. So the value of your panels depends less on how much they produce than on two things you can change: the rate you are billed on, and how much of your use happens while the sun is up.
Generation does not equal credit
That is LG&E and KU’s own phrase for a common solar bill surprise. Your inverter app counts everything the panels make. Your bill sees only what passes through the meter: the energy you buy when the panels fall short, and the energy you send out when they make more than the house uses. Solar used inside the house never appears on the bill; it simply lowers what you buy.
In Kentucky, LG&E and KU net metering terms depend on when the system went into service:
- NMS-2 (systems first in service on or after September 24, 2021). Everything you buy is billed at your normal rate, and each exported kWh earns a dollar bill credit: $0.07089 at LG&E and $0.07534 at KU. Against LG&E’s Rate RS energy charge of $0.11499 per kWh (effective September 1, 2026, base charge before riders and taxes), a kWh used at home is worth about 4.4 cents more than the same kWh exported. At KU (Rate RS, $0.11396) the gap is about 3.9 cents.
- NMS-1 (in service before September 24, 2021). Credits are counted in kWh, and on a time-of-day rate they apply only within the same time-of-day block. LG&E will end NMS-1 on September 24, 2046 and move those customers to NMS-2.
Credits never become cash and never offset non-energy charges such as the basic service charge. Other states use other rules: California, for example, moved new solar customers to a net billing tariff for interconnection applications from April 15, 2023. The solar export page covers these rules in more depth.
Rate choice comes first
A time-of-use rate charges more in the evening and less overnight. For a solar home without a battery, that can cut the wrong way. The panels cover the daytime hours, which are rarely the expensive ones, and the evening is still bought at the peak price. Whether a time-of-use rate pays depends on how much of your evening use can move.
At LG&E and KU, the choice is between Rate RS and RTOD-Energy, an optional time-of-day rate that needs an AMI meter and is limited to 500 customers across the two residential time-of-day rates. Its summer on-peak window is 2 to 6 p.m. on weekdays by the clock (set in the tariff as 1 to 5 p.m. Eastern Standard Time), while panels are still producing. Its winter on-peak windows, 6 to 10 a.m. and 6 to 10 p.m., fall in hours with little or no sun. The rate engine reads these windows by season and day type, and your plan compares the rates you can choose using your own bills. Try the question in the rate plan comparison calculator.
Moving loads into solar hours
Without a battery, the schedule moves use, not stored energy. The loads worth moving are the ones that do not care exactly when they run:
- A heat pump water heater, which can reheat its tank at midday.
- A pool pump, which can run its daily hours in the sun.
- Laundry and the dishwasher, started on a delay timer.
- Pre-cooling on a hot afternoon, inside the comfort range you set.
- An EV that is parked at home during the day.
Each kWh moved from an evening hour into a sunny one is no longer bought, and one less kWh is exported. On a flat rate with NMS-2, that swap is worth the retail price minus the export credit; on a time-of-use rate, the peak price minus the export credit, which is much more. Flexible loads explains how Culni times each one, and where a load has no confirmed control path, the plan gives you the timer setting.
Example (fictional). Take the example home without its battery and without the car: 7.6 kW of solar making 36.3 kWh on a clear April weekday, and 29.0 kWh of household use. On the example rate (8 cents off-peak from 9 p.m. to 7 a.m., 14 cents from 7 a.m. to 4 p.m., 31 cents from 4 to 9 p.m., and a 7 cent export credit) the house buys 17.1 kWh, 7.2 of them in the peak, and exports 24.4 kWh. Now suppose the household moves 3.0 kWh of laundry and dishwashing from 6 to 8 p.m. to noon to 2 p.m., when the panels have surplus to spare.
| Net cost for the day | Example time-of-use rate | Flat comparison rate (13 cents) |
|---|---|---|
| Before the move | $1.35 | $0.52 |
| After the move | $0.63 | $0.34 |
| Difference | $0.72 | $0.18 |
The move is worth four times as much on the time-of-use rate, yet the flat rate still costs less on this day: the house still buys 4.2 kWh in the peak. Assumptions: the same 7 cent export credit on both rates, fixed charges left out, one clear spring weekday only. Cloudy days, winter, weekends and your real rate change the result, so a real plan compares every day type against your bills.
Limits worth knowing
- Without a battery or flexible loads, there is little for a schedule to move. If your evening use is mostly cooking and lighting, the plan may simply tell you which rate to stay on.
- Culni cannot change your export credit, and it does not touch inverter export settings or your interconnection agreement.
- Rate eligibility is the utility’s decision, and a customer who leaves RTOD-Energy for Rate RS cannot return for 12 months.
- Production in your app and credits on your bill will not match. The monthly bill check explains the gap.
Considering storage? Battery homes explains when a battery pays on your rate and when it mostly adds backup.
What you send and what you get
Send your utility and rate plan, your net metering terms (NMS-1 or NMS-2 in Kentucky), a recent bill and a list of the appliances that could move. You get your rate decoded, a comparison of the rates you can choose, the loads worth moving with the hours to move them to, and the estimated value with every assumption shown. The utility bill checklist shows where to find each item before you send it through Check my home.
TodayYour turn
Send your rate and your devices
Your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan: your rate decoded, which devices can connect, the daily schedule and its estimated value with every assumption shown.
Remote. No site visit needed.