8 to 11 a.m.
11 a.m. to 5 p.m.
in the example home
Solar export
Which solar to use at home, store for later or send to the grid, under your net metering rules.
- 8 a.m. to 11 a.m. surplus stored in the battery
- 11 a.m. to 5 p.m. surplus exported
- You send
- Net metering tariff, system size, inverter, in-service date
- You get
- What earns credit, what does not, and what each kWh is worth
- Covers
- NMS-1, NMS-2 and net billing rules
- Limits
- Cannot change your credit or interconnection settings

“Generation does not equal credit.” That line comes from LG&E and KU’s own net metering page, and it explains most solar bill confusion. Your inverter app counts every kWh the panels make. The utility’s net meter “records only the energy you produce that flows onto” the grid. Solar the house uses as it is produced never reaches the meter as an export; it shows up on the bill as energy you did not buy. So the useful question about each kWh of solar is not how much you made, but where it went and what that was worth.
Three places a kWh of solar can go
| Where it goes | What it is worth |
|---|---|
| Used in the house as it is produced | The retail price you did not pay in that hour |
| Stored in the battery and used later | The price in the hour it is used, less storage losses (NREL uses 85% round-trip efficiency as representative) |
| Exported to the grid | Whatever your net metering tariff credits for it |
Culni compares the three for each hour, using your decoded rate, and sends surplus to the most valuable use your equipment allows.
Kentucky: NMS-1 and NMS-2
Kentucky law (KRS 278.466) requires every retail electric supplier to offer net metering to eligible customer-generators until cumulative net metering capacity reaches 1% of its single-hour peak load. The Public Service Commission sets export compensation through ratemaking, as a dollar-denominated bill credit each billing period; excess credit carries forward, with no cash refund when the account closes. Systems in service before the Commission’s first compensation order keep their existing terms, including the one-for-one kWh credit, for 25 years at those premises, even if the home is sold.
At LG&E and KU that produces two tariffs:
| NMS-1 | NMS-2 | |
|---|---|---|
| Who | Systems in service before September 24, 2021 | Systems first in service on or after September 24, 2021, up to 45 kW |
| Credit | kWh for kWh; on a time-of-day rate, only within the same time-of-day block | A dollar bill credit per kWh exported: $0.07089 at LG&E, $0.07534 at KU |
| What the credit offsets | Energy you buy, kWh for kWh | Only the energy charge and per-kWh riders |
| How long | LG&E will end NMS-1 on September 24, 2046 and move customers to NMS-2 | The current tariff (sheets effective February 16, 2026) |
Under NMS-2, all the energy you buy is billed at the standard rate. LG&E’s Rate RS energy charge is $0.11499 per kWh and KU’s is $0.11396 (effective September 1, 2026, before riders and taxes). So at LG&E, a kWh of solar used at home is worth about 4.4 cents more than the same kWh exported; at KU, about 3.9 cents. The LG&E and KU net metering page adds two rules: credits “never result in cash payments”, and they never offset non-energy charges such as the basic service charge.
What that means for the schedule:
- On NMS-2, every kWh of surplus used at home instead of bought is worth the gap between retail price and credit. Storing it in a battery pays when the price in the hour it is used, after losses, beats the credit.
- On NMS-1 with a flat rate, an exported kWh offsets a bought kWh one for one, so pushing solar through the battery mostly adds storage losses. The value of a schedule there comes from backup, from a time-of-day rate, or from planning for the move to NMS-2.
- On NMS-1 with a time-of-day rate, credits stay in the block where they were earned, so the hour of export matters.
Net billing elsewhere: California
Other states have moved further from one-for-one credits. In California, the CPUC adopted decision D.22-12-056 on December 15, 2022, establishing the Net Billing Tariff as the successor to NEM2. It applies to customers who submit an interconnection application on or after April 15, 2023. Under net billing, exports earn a credit set separately from the retail price, so, as under NMS-2, both the hour you export and the hour you use energy matter.
What the schedule does with surplus
In a typical order of value:
- Cover the house as the panels produce.
- Run flexible loads in surplus hours: the water heater, the pool pump, a load of laundry.
- Charge the battery when the stored energy will replace a more expensive hour later (see battery scheduling).
- Export the rest.
Example (fictional). On a clear April weekday the example home’s 7.6 kW system produces 36.3 kWh. With the Culni schedule, about 11.9 kWh covers the house directly. The battery stores about 8.5 kWh of morning surplus until it is full at about 11 a.m. From 11 a.m. to 5 p.m. the remaining 15.9 kWh is exported at the example credit of 7 cents, a $1.12 credit. From 5 to 9 p.m. the battery returns 7.2 kWh to the house in place of 31 cent peak energy, about $2.23 worth; exported instead, those 8.5 kWh would have earned about $0.59. Notice what the schedule did not do: it did not maximize self-consumption. It exports more than the battery’s default mode does (15.9 kWh against 12.7) and the day still costs less, because the value comes from which hours the stored energy replaces. One clear spring weekday is not a month or a year; walk through it on the example home page.
What Culni cannot change
- The credit. Your regulator and your tariff set it.
- Your tariff. In Kentucky, NMS-1 or NMS-2 follows from your system’s in-service date; nothing in the schedule moves you between them.
- Interconnection settings. Export limits and inverter settings stay within your interconnection agreement and the manufacturer’s limits. Kentucky law requires generating systems and interconnection equipment to meet NEC, IEEE and accredited testing laboratory safety and power quality standards, and those settings stay with your installer and your utility.
What you send and what you get
Send your net metering tariff (NMS-1 or NMS-2 in Kentucky, or your state’s equivalent), the system size, the inverter make and model, the in-service date if you know it, and a bill that shows exported kWh. You get an explanation of what on your bill earns credit and what does not, the value of a kWh used at home against a kWh exported, and the hours the schedule uses, stores and exports solar. To try your own numbers, use the solar self-consumption calculator or the net metering credit calculator.
TodayYour turn
Send your rate and your devices
Your utility and rate plan, one recent bill and the devices you have or plan. We reply with a written home energy plan: your rate decoded, which devices can connect, the daily schedule and its estimated value with every assumption shown.
Remote. No site visit needed.